presentation
This commit is contained in:
@@ -317,7 +317,7 @@ The \acs{FR} fusion model was evaluated on the \acs{MOS} train set and compared
|
||||
\label{tab:tid2013-fusion-mos-test}
|
||||
\begin{tabular}{lcccc}
|
||||
\hline
|
||||
\textbf{Model} & \textbf{\acs{PLCC}} & \textbf{\acs{SRCC}} & \textbf{\acs{MSE}} & \textbf{\acs{MAE}} \\
|
||||
\textbf{Metric} & \textbf{\acs{PLCC}} & \textbf{\acs{SRCC}} & \textbf{\acs{MSE}} & \textbf{\acs{MAE}} \\
|
||||
\hline
|
||||
\acs{pMOS-SSIM+} (ours) & \textbf{0.9264} & \textbf{0.9174} & \textbf{39.69} & \textbf{4.863} \\
|
||||
\acs{MS-SSIM} & 0.7640 & 0.7550 & 2564 & 48.76 \\
|
||||
@@ -409,9 +409,7 @@ We further evaluated the \acs{pMOS-NoisyTID} metric on individual groups of refe
|
||||
\caption{\acs{TID}2013 reference images from the test set.}
|
||||
\end{figure}
|
||||
|
||||
\autoref{tab:tid_nr_scores} compares \acs{pMOS-NoisyTID} predictions to standard \acs{NR-IQA} metrics, showing clear improvements.
|
||||
|
||||
\autoref{tab:tid_nr_scores} shows a clear gap between standard \acs{NR-IQA} baselines and the proposed \acs{pMOS-NoisyTID}. Traditional blind metrics such as \acs{NIQE}, \acs{PIQE} and \acs{BRISQUE} exhibit weak correlation with human judgements on \acs{TID}2013, whereas \acs{pMOS-NoisyTID} aligns substantially better with subjective quality, achieving \acs{PLCC} = 0.6860, and \acs{SRCC} = 0.5591. These results support our two-stage approach, \acs{pMOS} fusion followed by \acs{NR} model training, as a more reliable and generalizable route to \acs{NR-IQA}, capturing perceptual quality variations in general images beyond the facial domain of \acs{FRLL}.
|
||||
\autoref{tab:tid_nr_scores} compares \acs{pMOS-NoisyTID} predictions to standard \acs{NR-IQA} metrics, showing clear improvements. There's a clear gap between standard \acs{NR-IQA} baselines and the proposed \acs{pMOS-NoisyTID}. Traditional blind metrics such as \acs{NIQE}, \acs{PIQE} and \acs{BRISQUE} exhibit weak correlation with human judgements on \acs{TID}2013, whereas \acs{pMOS-NoisyTID} aligns substantially better with subjective quality, achieving \acs{PLCC} = 0.6860, and \acs{SRCC} = 0.5591. These results support our two-stage approach, \acs{pMOS} fusion followed by \acs{NR} model training, as a more reliable and generalizable route to \acs{NR-IQA}, capturing perceptual quality variations in general images beyond the facial domain of \acs{FRLL}.
|
||||
|
||||
\begin{table}[htpb]
|
||||
\centering
|
||||
|
||||
Reference in New Issue
Block a user