teste
This commit is contained in:
@@ -0,0 +1 @@
|
||||
A persistent gap remains between standard Image Quality Assessment (IQA) metrics and human perceptual judgments, typically quantified via Mean Opinion Scores (MOS). This poses a key challenge in applications where perceived quality impacts performance, such as facial recognition. We introduce a new no-reference Face Image Quality Assessment (FIQA) metric, developed within a Full-to-No-Reference learning framework. The process begins with a full-reference fusion model trained to regress classical IQA scores against human MOS on a labeled subset. This model is used to generate pseudo-MOS scores for the full dataset. These labels then supervise a no-reference deep regressor based on ResNet-18 features, producing a perceptually aligned metric that estimates quality directly from distorted facial images. We tested our approach in the context of steganographically degraded facial images, showing its effectiveness in scenarios involving subtle distortions and limited human annotations.
|
||||
@@ -0,0 +1 @@
|
||||
Mantém-se uma discrepância persistente entre as métricas padrão de Avaliação da Qualidade de Imagem (IQA) e os juízos perceptivos humanos, geralmente quantificados através dos Mean Opinion Scores (MOS). Esta divergência constitui um desafio central em aplicações onde a qualidade percebida afeta o desempenho, como no reconhecimento facial. Apresentamos uma nova métrica de Avaliação da Qualidade de Imagens Faciais (FIQA) sem referência, desenvolvida no âmbito de uma estrutura de aprendizagem do tipo Full-to-No-Reference. O processo tem início com um modelo de fusão com referência completa, treinado para fazer a regressão de métricas IQA clássicas em função dos MOS humanos num subconjunto anotado. Este modelo é então utilizado para gerar pseudo-MOS para o conjunto completo de dados. Estes rótulos supervisionam depois um regressor profundo sem referência baseado em características extraídas da ResNet-18, originando uma métrica alinhada com a perceção humana que estima a qualidade diretamente a partir de imagens faciais degradadas. Testámos a nossa abordagem no contexto de imagens faciais afetadas por esteganografia, demonstrando a sua eficácia em cenários com distorções subtis e anotações humanas limitadas.
|
||||
@@ -10,10 +10,8 @@ IQA methods are generally categorized as subjective or objective. Subjective ass
|
||||
|
||||
Subjective image quality assessment relies on human evaluations to generate ground-truth perceptual scores, often in the form of Mean Opinion Scores (MOS) or Difference Mean Opinion Scores (DMOS). These scores are typically collected under controlled conditions following international standards such as ITU-R BT.500~\cite{itu_bt500_2023} or ITU-T P.910~\cite{itu_p910_2008}. Subjective assessment captures nuances of human vision that are difficult to model algorithmically, making it essential for validating and benchmarking objective IQA models~\cite{ponomarenko_tid2013, zaric_comparison_objective_subjective}. However, it is inherently limited by inter-observer variability, cultural or demographic bias, and the logistical costs associated with large-scale studies~\cite{ghadiyaram_crowdsourced_study_2016}. Crowdsourcing platforms like Amazon Mechanical Turk~\cite{amazon_mturk} have recently enabled more scalable data collection, though at the expense of environmental control and consistency.
|
||||
|
||||
|
||||
Objective IQA methods are commonly divided into three categories: full-reference (FR), reduced-reference (RR), and no-reference (NR). FR-IQA assumes access to an undistorted reference image and compares it to the distorted version using perceptual models~\cite{wang_ssim_2004, sheikh_ifc_2005, zhang_fsim_2011}. RR-IQA methods extract partial information from the reference image, enabling a compromise between performance and practicality~\cite{wang_wavelet_statistics_2005, li_divisive_normalization_2009}. NR-IQA, also known as blind IQA, operates without any reference and is considered the most challenging, requiring models to infer quality based solely on the distorted image~\cite{mittal_brisque_2012, bosse_deep_nriqa_2018}.
|
||||
|
||||
|
||||
Facial Image Quality Assessment (FIQA) is a specialized subfield of IQA that aims to quantify the quality of facial images with respect to their utility in downstream biometric or analytic tasks. Unlike general-purpose IQA, FIQA must account for both perceptual attributes (e.g., blur, noise) and task-specific considerations such as facial pose, occlusion, expression, and alignment~\cite{hernandez_fiqanet_2020, boutros_iqface_2021, li_biofacenet_2021}. High-quality face images are crucial for ensuring the accuracy and fairness of face recognition systems, particularly in security, forensics, and surveillance domains~\cite{xu_secureqnet_2020, luo_deepiq_2018}. Consequently, FIQA models often incorporate features from deep face recognition networks to align quality predictions with identity discrimination performance~\cite{FaceMetric2025}. This task-oriented nature of FIQA makes it fundamentally different from traditional perceptual quality assessment.
|
||||
|
||||
FIQA systems have been shown to produce different quality scores depending on a person's age, gender, or skin tone~\cite{jo_ifqa_2024, FaceMetric2025}. These differences often happen because the training data includes more examples from certain groups and fewer from others. For example, images of people with darker skin or non-frontal poses are often less common in training sets, which leads to lower quality scores for those individuals~\cite{kanwisher2006fusiform}. This can cause face recognition systems to perform worse for some groups than others, raising serious concerns about fairness.
|
||||
@@ -31,7 +29,7 @@ A particularly relevant subclass of steganography for identity documents is prin
|
||||
|
||||
\section{Problem Statement}\label{sec:problem_statement}
|
||||
|
||||
Despite significant advances in FIQA, current approaches struggle to capture task-specific degradations introduced by modern steganographic techniques. Existing methods often rely on handcrafted features~\cite{henniger2020biosig}, supervised quality learning~\cite{hernandez2019faceqnet, meng2021magface, terhorst2020serfiq}, or rank-based formulations~\cite{liu2017rankiqa}. However, these frameworks are typically trained on standard datasets and are not optimized to handle distortions that preserve visual fidelity while disrupting biometric utility. Moreover, demographic and perceptual biases embedded in training data~\cite{babnik2022} raise concerns about the fairness and generalizability of FIQA systems. This is especially problematic for applications involving MRTDs, where regulation mandates consistent quality but does not address ethical or perceptual variance~\cite{icao_2015, iso_iec29794-5_2010}. Therefore, there is a critical need for NR-IQA methods that can detect subtle, high-impact degradations in facial images, particularly those arising from adversarial steganography while accounting for demographic fairness and interpretability.
|
||||
Despite significant advances in FIQA, current approaches struggle to capture task-specific degradations introduced by modern steganographic techniques. Existing methods often rely on handcrafted features~\cite{henniger2020biosig}, supervised quality learning~\cite{hernandez2019faceqnet, meng2021magface, terhorst2020serfiq}, or rank-based formulations~\cite{liu2017rankiqa}. However, these frameworks are typically trained on standard datasets and are not optimized to handle distortions that preserve visual fidelity while disrupting utility. Moreover, demographic and perceptual biases embedded in training data~\cite{babnik2022} raise concerns about the fairness and generalizability of FIQA systems. This is especially problematic for applications involving MRTDs, where regulation mandates consistent quality but does not address ethical or perceptual variance~\cite{icao_2015, iso_iec29794-5_2010}. Therefore, there is a critical need for NR-IQA methods that can detect subtle, high-impact degradations in facial images, particularly those arising from adversarial steganography while accounting for demographic fairness and interpretability.
|
||||
|
||||
Traditional IQA frameworks tend to generalize across domains, but real-world applications demand task-aware assessment strategies. In the context of facial biometrics, image quality must be evaluated not only in terms of visual fidelity but also in terms of its impact on recognition performance and fairness. This motivates the development of application-specific IQA pipelines that consider context-dependent factors, such as demographic variability and task utility. At the same time, the perceptual dimension of image quality remains central. Human observers are still used as the ground truth in subjective assessments~\cite{ITU-R-BT500, mos2016}, yet NR-IQA models often diverge from these judgments, especially in complex scenarios involving subtle degradations or diverse populations. To bridge this gap, new strategies are needed to align NR-IQA with subjective perception—either by integrating perceptual priors, modeling bias sources, or learning from pseudo-MOS annotations that reflect human preferences~\cite{chen2021pseudo, jin2020pipal}.
|
||||
|
||||
|
||||
@@ -35,8 +35,6 @@ Beyond laboratory-controlled protocols, crowdsourcing has emerged as a scalable
|
||||
|
||||
Several benchmark datasets have been curated to support the development and evaluation of IQA models. The LIVE~\cite{sheikh2006image}, TID2013~\cite{pnsr2003}, and CSIQ~\cite{ma2011psnr} datasets follow ITU-R BT.500-compliant procedures, offering high-quality MOS/DMOS annotations across a range of distortion types. More recent datasets, such as PIPAL~\cite{jin2020pipal} and KonIQ-10k~\cite{mos2016}, leverage crowdsourced assessments to achieve broader coverage of real-world content and perceptual variance. These datasets not only facilitate benchmarking but also allow for training data-driven IQA models in both full and no-reference scenarios. Nonetheless, domain-specific datasets, particularly those for biometric, medical, or forensic applications, remain scarce, limiting the generalizability of learned metrics in those contexts.
|
||||
|
||||
While subjective assessments offer the most faithful representation of human perception, they are costly, time-consuming, and difficult to replicate at scale. This has motivated the development of objective IQA algorithms that aim to approximate human judgments using computational models.
|
||||
|
||||
|
||||
\section{Objective IQA}\label{sec:objective_iqa}
|
||||
|
||||
@@ -44,22 +42,23 @@ Objective IQA refers to the automatic estimation of visual quality using computa
|
||||
|
||||
These metrics can be further characterized by the domain in which they operate and the spectral representation they use. The domain refers to the signal space employed during computation. Classical metrics operate in the spatial domain, comparing pixel intensities directly, as seen in PSNR and SSIM~\cite{Wang2004SSIM}. Others use the frequency domain, employing transforms such as the discrete cosine transform (DCT) or wavelet decompositions to capture structural differences, as in VIF~\cite{sheikh_vif_2006} and IFC~\cite{sheikh2005ifc}. A third group targets the spectral domain, often used in remote sensing, where images are compared across multiple wavelength bands using metrics such as ERGAS~\cite{Ranchin2000ERGAS} and SAM~\cite{Kruse1993SAM}. Additional domains include gradient-based methods that emphasize edge strength or direction, such as GMSD~\cite{Xue2014GMSD}, and deep feature domains, which assess perceptual similarity using activations from convolutional neural networks trained on natural images, as in LPIPS~\cite{zhang2018lpips} and DISTS~\cite{ding2020dists}.
|
||||
|
||||
The spectral representation, or color spectrum, denotes the channel configuration used by the metric. Many classical approaches focus solely on the luminance channel (Y), which aligns closely with human perception~\cite{sheikh_vif_2006, chandler2007vsnr}. Others compute scores over grayscale or full RGB images, as seen in FSIM~\cite{zhang2011fsim} and its color extension FSIMc. Some metrics operate in alternative color spaces such as YCbCr or CIELab~\cite{Wang2002PQM}, while hyperspectral or multiband metrics process dozens of spectral channels, particularly in remote sensing applications~\cite{Zhou1998SCC,Alparone2008QNR}. Table~\ref{tab:fr_iqa_metrics} summarizes the 41 IQA metrics considered in this work, detailing their reference type, computational domain, publication year, number of tested databases, and spectral characteristics.
|
||||
The spectral representation, or color spectrum, denotes the channel configuration used by the metric. Many classical approaches focus solely on the luminance channel (Y), which aligns closely with human perception~\cite{sheikh_vif_2006, chandler2007vsnr}. Others compute scores over grayscale or full RGB images, as seen in FSIM~\cite{zhang2011fsim} and its color extension FSIMc. Some metrics operate in alternative color spaces such as YCbCr or CIELab~\cite{Wang2002PQM}, while hyperspectral or multiband metrics process dozens of spectral channels, particularly in remote sensing applications~\cite{Zhou1998SCC,Alparone2008QNR}. Table~\ref{tab:fr_iqa_metrics} summarizes the 40 IQA metrics considered in this work, detailing their reference type, computational domain, publication year, number of tested databases, and spectral characteristics.
|
||||
|
||||
|
||||
|
||||
\begin{longtable}{l l l c c l}
|
||||
\caption{Summary of the 41 IQA metrics used}\label{tab:fr_iqa_metrics}\\
|
||||
\hline
|
||||
\hline % chktex 44
|
||||
\textbf{Metric} & \textbf{Type} & \textbf{Domain} & \textbf{Year} & \textbf{Tested Databases} & \textbf{Spectrum}\\
|
||||
\hline
|
||||
\endfirsthead
|
||||
\multicolumn{6}{r}{\small\itshape(continuation)}\\
|
||||
\hline
|
||||
\hline % chktex 44
|
||||
\endfirsthead % chktex 1
|
||||
\multicolumn{6}{r}{\small\itshape(continuation)}\\ % chktex 6
|
||||
\hline % chktex 44
|
||||
\textbf{Metric} & \textbf{Type} & \textbf{Domain} & \textbf{Year} & \textbf{Tested Databases} & \textbf{Spectrum}\\
|
||||
\hline
|
||||
\endhead
|
||||
\hline
|
||||
\endfoot
|
||||
\hline % chktex 44
|
||||
\endhead % chktex 1
|
||||
\hline % chktex 44
|
||||
\endfoot % chktex 1
|
||||
|
||||
C-SSIM~\cite{Hassan2017CSSIM} & FR & spatial & 2017 & 2 & RGB \\
|
||||
CW-SSIM~\cite{Sampat2009CWSSIM} & FR & complex wavelet & 2009 & 1 & grayscale \\
|
||||
@@ -83,7 +82,6 @@ The spectral representation, or color spectrum, denotes the channel configuratio
|
||||
MS-SSIM~\cite{Wang2003MSSSIM} & FR & spatial & 2003 & 1 & grayscale \\
|
||||
MSE~\cite{Gonzalez2008DIP} & FR & spatial & N/A & --- & grayscale \\
|
||||
PQM~\cite{Wang2002PQM} & NR & spatial & 2002 & 1 & Y (JPEG) \\
|
||||
PIQE~\cite{Venkatanath2015PIQE} & NR & spatial & 2015 & 1 & RGB \\
|
||||
PSNR~\cite{Gonzalez2008DIP} & FR & spatial & N/A & --- & grayscale \\
|
||||
PSNR-B~\cite{Yim2011PSNRB} & FR & spatial & 2011 & 1 & Y (luma) \\
|
||||
R-SSIM~\cite{Malpica2008RSSIM} & FR & spatial (depth) & 2009 & 1 & depth map \\
|
||||
@@ -98,11 +96,10 @@ The spectral representation, or color spectrum, denotes the channel configuratio
|
||||
VIF~\cite{Sheikh2006VIF} & FR & wavelet & 2006 & 1 & Y (luma) \\
|
||||
VIFc~\cite{Sheikh2006VIF} & FR & wavelet & 2006 & 1 & Y/CbCr \\
|
||||
VIFp~\cite{Sheikh2005VIFp} & FR & pixel-domain & 2005 & 1 & Y (luma) \\
|
||||
VSNR~\cite{Chandler2007VSNR} & FR & wavelet & 2007 & 1 & Y (luma) \\
|
||||
VSNR~\cite{chandler2007vsnr} & FR & wavelet & 2007 & 1 & Y (luma) \\
|
||||
WaDIQaM~\cite{Bosse2018WaDIQaM} & FR & deep features & 2018 & 3 & RGB \\
|
||||
W-SSIM~\cite{Engelke2011WSSIM} & FR & spatial & 2011 & 1 & grayscale \\
|
||||
$D_{\lambda}$ (QNR)~\cite{Alparone2008QNR} & FR & spectral/spatial & 2008 & 1 & multi-band \\
|
||||
|
||||
\end{longtable}
|
||||
|
||||
\subsection{Full-Reference IQA}\label{sec:full_reference_iqa}
|
||||
@@ -162,8 +159,7 @@ The ERGAS (Erreur Relative Globale Adimensionnelle de Synthèse) metric expresse
|
||||
\begin{equation}
|
||||
\text{ERGAS} = 100 \cdot \frac{h}{l} \cdot \sqrt{ \frac{1}{N} \sum_{i=1}^{N} {\left( \frac{\text{RMSE}_i}{\mu_i} \right)}^2 }
|
||||
\end{equation}
|
||||
|
||||
where \( h \) and \( l \) are the spatial resolutions of the high- and low-resolution images respectively, \( \text{RMSE}_i \) is the RMSE of band \( i \), and \( \mu_i \) is the mean of the reference band.
|
||||
where $h$ and $l$ are the spatial resolutions of the high and low resolution images respectively, $\text{RMSE}_i$ is the RMSE of band $i$, and $\mu_i$ is the mean of the reference band.
|
||||
|
||||
These metrics are particularly useful when high pixel fidelity is essential, but they often fail to align with human perception, especially in cases where structural or semantic information is preserved.
|
||||
|
||||
@@ -177,7 +173,6 @@ The Structural Similarity Index (SSIM) compares local image patches between the
|
||||
\begin{equation}
|
||||
\text{SSIM}(x, y) = \frac{(2\mu_x \mu_y + C_1)(2\sigma_{xy} + C_2)}{(\mu_x^2 + \mu_y^2 + C_1)(\sigma_x^2 + \sigma_y^2 + C_2)}
|
||||
\end{equation}
|
||||
|
||||
where $\mu_x$ and $\mu_y$ are the local means, $\sigma_x^2$ and $\sigma_y^2$ are the local variances, $\sigma_{xy}$ is the local covariance, and $C_1$, $C_2$ are stabilizing constants.
|
||||
|
||||
Multiscale SSIM (MS-SSIM) extends SSIM by computing similarity at multiple image scales. It is defined as:
|
||||
@@ -193,7 +188,6 @@ The Feature Similarity Index (FSIM) combines phase congruency (PC) and gradient
|
||||
\begin{equation}
|
||||
\text{FSIM}(x, y) = \frac{\sum_{i \in \Omega} T(i) \cdot PC_m(i)}{\sum_{i \in \Omega} PC_m(i)}
|
||||
\end{equation}
|
||||
|
||||
where $T(i)$ is a similarity function combining gradient and phase congruency similarity at pixel $i$, and $PC_m(i)$ is the maximum phase congruency across both images.
|
||||
|
||||
The Gradient Magnitude Similarity Deviation (GMSD) is based on the standard deviation of pixel-wise gradient similarity maps:
|
||||
@@ -205,7 +199,6 @@ The Gradient Magnitude Similarity Deviation (GMSD) is based on the standard devi
|
||||
\begin{equation}
|
||||
\text{GMSD}(x, y) = \sqrt{\frac{1}{N} \sum_{i=1}^{N} {\left( \text{GMS}(i) - \overline{\text{GMS}} \right)}^2}
|
||||
\end{equation}
|
||||
|
||||
where $G_x(i)$ and $G_y(i)$ are gradient magnitudes of the reference and distorted images, and $C$ is a small constant.
|
||||
|
||||
The Spectral Residual Similarity Index (SR-SIM) evaluates similarity by combining spectral residual saliency and gradient magnitude:
|
||||
@@ -221,7 +214,6 @@ The Information-Weighted Structural Similarity Index (IW-SSIM) assigns greater i
|
||||
\begin{equation}
|
||||
\text{IW-SSIM}(x, y) = \frac{\sum_{i=1}^{N} w_i \cdot \text{SSIM}_i(x, y)}{\sum_{i=1}^{N} w_i}
|
||||
\end{equation}
|
||||
|
||||
where $w_i$ is the information weight for window $i$, often computed using local entropy or local variance.
|
||||
|
||||
The Wavelet-based SSIM (W-SSIM) extends SSIM into the complex wavelet domain. Instead of operating directly on image intensities, it evaluates phase consistency across wavelet subbands. The general form follows a similar structure to SSIM, applied to wavelet coefficients:
|
||||
@@ -237,7 +229,6 @@ The Edge Strength Similarity Metric (ESSIM or ESIM) modifies SSIM by replacing t
|
||||
\begin{equation}
|
||||
\text{ESSIM}(x, y) = \frac{(2\mu_x \mu_y + C_1)(2E(x, y) + C_2)}{(\mu_x^2 + \mu_y^2 + C_1)(E(x, x) + E(y, y) + C_2)}
|
||||
\end{equation}
|
||||
|
||||
where $E(x, y)$ denotes the dot product of edge maps from the two images.
|
||||
|
||||
While perceptual similarity metrics approximate human visual perception by analyzing structural and saliency-based cues, they remain largely deterministic and handcrafted.
|
||||
@@ -251,7 +242,6 @@ The IFC models image patches in the wavelet domain using Gaussian scale mixture
|
||||
\begin{equation}
|
||||
\text{IFC}(x, y) = \sum_{i \in \Omega} I(C_{x,i}; C_{y,i} \mid z_i)
|
||||
\end{equation}
|
||||
|
||||
where $C_{x,i}$ and $C_{y,i}$ are wavelet coefficients of the reference and distorted images in patch $i$, and $z_i$ is a local variance parameter estimated under a GSM model. The total information is accumulated over all image patches $\Omega$.
|
||||
|
||||
The VIF index extends this by incorporating a model of the human visual system. It computes the ratio of information that can be extracted by a hypothetical observer from the distorted image versus the reference:
|
||||
@@ -269,7 +259,6 @@ Another extension is VIFc, which extends the VIF model to handle color images~\c
|
||||
\begin{equation}
|
||||
\text{VIFc}(x, y) = \sum_{k \in \{Y,Cb,Cr\}} w_k \cdot \text{VIF}_k(x, y)
|
||||
\end{equation}
|
||||
|
||||
where $w_k$ are empirically determined weights that reflect the perceptual importance of each component. Typically, the luminance channel (Y) receives the highest weight due to its dominant role in human perception.
|
||||
|
||||
These variants preserve the conceptual integrity of the original VIF model while offering improved flexibility for different input modalities and computational budgets.
|
||||
@@ -283,7 +272,6 @@ The LPIPS metric computes the distance between deep feature maps of a reference
|
||||
\begin{equation}
|
||||
\text{LPIPS}(x, y) = \sum_{l} \frac{1}{H_l W_l} \sum_{h=1}^{H_l} \sum_{w=1}^{W_l} \| w_l \odot (\hat{f}_l^x(h, w) - \hat{f}_l^y(h, w)) \|_2^2
|
||||
\end{equation}
|
||||
|
||||
where $\hat{f}_l^x$ and $\hat{f}_l^y$ are the normalized feature maps at layer $l$ for images $x$ and $y$, respectively, with spatial dimensions $H_l \times W_l$. The weights $w_l$ are learned scalars for each channel, and $\odot$ denotes element-wise multiplication.
|
||||
|
||||
The DISTS metric combines feature similarity and texture similarity between corresponding feature maps:
|
||||
@@ -291,7 +279,6 @@ The DISTS metric combines feature similarity and texture similarity between corr
|
||||
\begin{equation}
|
||||
\text{DISTS}(x, y) = \sum_{l} \alpha_l \cdot S_l(x, y) + \beta_l \cdot T_l(x, y)
|
||||
\end{equation}
|
||||
|
||||
where $S_l(x, y)$ is the structure similarity component computed as the cosine similarity between deep features at layer $l$, and $T_l(x, y)$ is the texture similarity component, often based on the mean and variance of feature activations. The coefficients $\alpha_l$ and $\beta_l$ are learned to balance structure and texture contributions for each layer $l$.
|
||||
|
||||
WaDIQaM-FR learns a patch-based quality prediction model using paired deep features from the reference image $x$ and the distorted image $y$. Given a patch pair $(x_i, y_i)$, deep features are extracted using a shared-weight CNN encoder, and the resulting representations are concatenated and passed through a regression network to predict a local quality score $q_i$. The final quality score is the weighted average over all patches:
|
||||
@@ -299,7 +286,6 @@ WaDIQaM-FR learns a patch-based quality prediction model using paired deep featu
|
||||
\begin{equation}
|
||||
Q(x, y) = \sum_{i=1}^{N} w_i \cdot q_i
|
||||
\end{equation}
|
||||
|
||||
where $q_i = f_{\theta}(x_i, y_i)$ is the predicted quality for patch $i$, $w_i$ is a learned spatial weight indicating the perceptual relevance of patch $i$, and $N$ is the total number of patches. The function $f_{\theta}$ denotes the trained regression model with parameters $\theta$.
|
||||
|
||||
During training, the network minimizes the error between predicted quality scores and human-annotated MOS or DMOS labels using an appropriate loss function (e.g., MSE or Huber loss). Unlike LPIPS or DISTS, WaDIQaM does not rely on pretrained networks, allowing it to adapt feature representations to the task of quality prediction.
|
||||
@@ -308,10 +294,46 @@ In summary, full-reference IQA models span a spectrum from simple error-based me
|
||||
|
||||
\subsection{No-Reference IQA}\label{sec:no_reference_iqa}
|
||||
|
||||
No-reference image quality assessment (NR-IQA) seeks to estimate perceptual quality without access to a reference image. This setting reflects practical use cases such as user-generated content, mobile imaging, and surveillance, where undistorted ground-truth images are typically unavailable. NR-IQA is inherently ill-posed, as models must infer the type and severity of distortion solely from the image under test. Among the earliest approaches, several models are tailored to specific distortion types. JPEG, the most widely used lossy image compression standard, operates by dividing images into $8 \times 8$ blocks, applying the discrete cosine transform (DCT), quantizing the coefficients, and entropy-coding the result~\cite{wallace1992jpeg}. While efficient, this block-based approach introduces artifacts such as blocking, ringing, and loss of fine detail, particularly at low bitrates. The PQM metric~\cite{wang2002pqm} exploits these properties by modeling visual thresholds under JPEG quantization. In contrast, PIQE~\cite{venkatanath2015piqe} adopts a more general framework, detecting local distortions such as blur, noise, and blockiness using block-level statistical analysis. More recently, SPIQ~\cite{chen2022spiq} applies a deep neural network to predict score distributions aligned with human opinion scores, achieving higher robustness and perceptual alignment across diverse content and distortion types.
|
||||
Among traditional NR-IQA techniques, PIQE~\cite{piqe2016} (Perception-based Image Quality Evaluator) and NIQE~\cite{mittal2013making} (Natural Image Quality Evaluator) are widely used due to their computational simplicity. PIQE begins by dividing the input image into non-overlapping $16 \times 16$ blocks, denoted $B_i$, and identifying distorted blocks based on edge content and local variance thresholds. For each block, it computes perceptual features using the gradient magnitude:
|
||||
\begin{equation}
|
||||
S_i = \frac{1}{|B_i|} \sum_{(x,y) \in B_i} \sqrt{ {\left( \frac{\partial I}{\partial x} \right)}^2 + {\left( \frac{\partial I}{\partial y} \right)}^2 },
|
||||
\end{equation}
|
||||
and noise, estimated by subtracting a low-pass filtered (LPF) version of the block:
|
||||
\begin{equation}
|
||||
N_i = \text{std}\left( B_i - \text{LPF}(B_i) \right).
|
||||
\end{equation}
|
||||
The global PIQE score is computed via a weighted aggregation over the distorted blocks, $\mathcal{D}$:
|
||||
\begin{equation}
|
||||
\text{PIQE} = \frac{1}{|\mathcal{D}|} \sum_{i \in \mathcal{D}} w_i \cdot ( \alpha S_i + \beta N_i + \gamma C_i ),
|
||||
\end{equation}
|
||||
where $w_i$ are confidence weights and $\alpha, \beta, \gamma$ are scaling factors for sharpness, noise, and contrast, respectively. The final score is scaled between 0 (best quality) and 100 (worst quality).
|
||||
|
||||
In contrast, NIQE is grounded in natural scene statistics (NSS), using a statistical deviation model to quantify perceptual degradation. First, it applies Mean Subtracted Contrast Normalization (MSCN) to locally standardize luminance:
|
||||
\begin{equation}
|
||||
\hat{I}(x, y) = \frac{I(x, y) - \mu(x, y)}{\sigma(x, y) + \epsilon},
|
||||
\end{equation}
|
||||
from which it extracts statistical features associated with Generalized Gaussian Distributions (GGD) and Asymmetric GGD (AGGD). A multivariate Gaussian (MVG) model with mean $\mu_r$ and covariance $\Sigma_r$ is estimated to a set of pristine images. During inference, the Mahalanobis distance between the test image features $\mathbf{f}_t$ and the natural image model is used to compute the NIQE score:
|
||||
\begin{equation}
|
||||
\text{NIQE}(\mathbf{f}_t) = \sqrt{ {(\mathbf{f}_t - \mu_r)}^T \Sigma_r^{-1} (\mathbf{f}_t - \mu_r) }.
|
||||
\end{equation}
|
||||
This formulation enables NIQE to operate in a completely opinion-unaware and unsupervised fashion, relying solely on deviations from natural image statistics to infer perceptual quality.
|
||||
|
||||
In contrast to traditional statistical NR-IQA methods, recent approaches such as SER-FIQ~\cite{terhorst2020serfiq} (Stochastic Embedding Robustness for Face Image Quality) and MagFace~\cite{meng2021magface} adopt deep learning-based strategies tailored specifically for facial image quality. SER-FIQ builds on the intuition that high-quality facial images produce consistent embeddings under stochastic dropout perturbations, while low-quality images result in more variable and unstable representations. Given a face image, a pre-trained face recognition model (e.g., ArcFace) with dropout enabled generates $T$ stochastic embeddings $\{\mathbf{e}_1, \mathbf{e}_2, \dots, \mathbf{e}_T\} \in \mathbb{R}^d$. The pairwise cosine similarities between these embeddings are then computed:
|
||||
\begin{equation}
|
||||
\text{sim}(\mathbf{e}_i, \mathbf{e}_j) = \frac{\mathbf{e}_i \cdot \mathbf{e}_j}{\|\mathbf{e}_i\| \|\mathbf{e}_j\|}, \quad \forall i,j \in \{1,\dots,T\}, i < j.
|
||||
\end{equation}
|
||||
The final SER-FIQ score is derived from the mean or standard deviation of the similarity matrix, often defined as:
|
||||
\begin{equation}
|
||||
\text{SER-FIQ} = \frac{1}{\binom{T}{2}} \sum_{i<j} \text{sim}(\mathbf{e}_i, \mathbf{e}_j),
|
||||
\end{equation}
|
||||
where higher scores indicate more stable (and thus higher-quality) facial representations. This method is fully unsupervised and exploits intrinsic model uncertainty as an indicator for quality.
|
||||
|
||||
MagFace, on the other hand, is a supervised approach that explicitly learns a quality-aware embedding space. It introduces a margin-adaptive loss that couples facial feature magnitude with image quality. For an embedding \( \mathbf{e} \in \mathbb{R}^d \), its \( L_2 \)-norm \( \|\mathbf{e}\| \) is used as a measure for quality. The classification loss is modified as:
|
||||
\begin{equation}
|
||||
\mathcal{L}_{\text{MagFace}} = -\log \frac{e^{s \cdot (\cos(\theta_y + m(\|\mathbf{e}\|)))}}{e^{s \cdot (\cos(\theta_y + m(\|\mathbf{e}\|)))} + \sum_{j \neq y} e^{s \cdot \cos(\theta_j)}},
|
||||
\end{equation}
|
||||
where \( \theta_y \) is the angle between \( \mathbf{e} \) and the weight vector of the correct class, \( s \) is a scaling factor, and \( m(\|\mathbf{e}\|) \) is a dynamic margin that increases with quality. The final MagFace quality score is proportional to the magnitude \( \|\mathbf{e}\| \), constrained during training to lie within a fixed interval \([l, u]\) for regularization. Unlike SER-FIQ, MagFace learns to embed quality-awareness directly into the feature space through supervision, enabling both verification and quality prediction in a unified framework.
|
||||
|
||||
The PQM metric operates in the JPEG compression domain and estimates quality based on the characteristics of the quantization matrix and the signal activity in each block. It computes a weighted distortion visibility index across blocks, with perceptual thresholds derived from luminance masking and contrast sensitivity~\cite{wang2002pqm}. In contrast, PIQE is a distortion-aware metric that segments the image into non-overlapping blocks and identifies artifacts using measures such as blockiness, noise, and blur~\cite{venkatanath2015piqe}. Blocks deemed distorted contribute to a pooled score based on localized deviations from natural image statistics. Both PQM and PIQE are deterministic, non-learning-based models that are efficient but limited in their ability to generalize across diverse content or unseen distortion types. SPIQ~\cite{chen2022spiq}, on the other hand, predicts a perceptual quality score distribution using a deep neural network trained on human opinion scores. It jointly models the mean and variance of subjective ratings, enabling more accurate prediction of both central tendency and confidence. Compared to traditional methods, SPIQ achieves superior correlation with subjective assessments, especially on authentic distortions, but requires significantly more training data and computational resources.
|
||||
|
||||
\subsection{Fusion-Based IQA Models}\label{sec:fusion_iqa}
|
||||
|
||||
@@ -319,13 +341,43 @@ To address the perceptual limitations of individual image quality metrics, sever
|
||||
|
||||
In parallel, the scarcity of large-scale human-labeled datasets has motivated weakly supervised learning strategies. Chen et al.~\cite{chen2021pseudo} generated pseudo-MOS labels by averaging outputs of multiple FR-IQA metrics. RankIQA~\cite{liu2017rankiqa} applied relative ranking supervision on synthetically degraded images to learn ordinal quality representations. Wu et al.~\cite{wu2020cascaded} used cascaded convolutional regressors trained on pseudo-MOS labels, demonstrating that pseudo-supervision can bootstrap learning when subjective ground truth is limited.
|
||||
|
||||
These developments support the feasibility of learning perceptual quality through fusion, either via model ensembles or by generating training supervision. Our approach builds on this principle: we construct a regression-based fusion model that aggregates multiple FR-IQA scores to predict perceptual quality, using human-labeled MOS as supervision.\@ This model is then applied to a larger unlabeled dataset to generate pseudo-MOS scores, which in turn are used to train a no-reference regressor. This hybrid full-to-no-reference framework enables scalable, perceptually grounded quality estimation even in the absence of pristine reference images.\@
|
||||
These developments support the feasibility of learning perceptual quality through fusion, either via model ensembles or by generating training supervision. Our approach builds on this principle: we construct a regression-based fusion model that aggregates multiple FR-IQA scores to predict perceptual quality, using human-labeled MOS as supervision. This model is then applied to a larger unlabeled dataset to generate pseudo-MOS scores, which in turn are used to train a no-reference regressor. This hybrid full-to-no-reference framework enables scalable, perceptually grounded quality estimation even in the absence of pristine reference images.
|
||||
|
||||
\section{Facial Image Quality assessment}\label{sec:fiqa}
|
||||
|
||||
Facial image quality assessment (FIQA) refers to the estimation of biometric utility from face images—typically in the context of face recognition, verification, or detection pipelines. Unlike generic no-reference IQA, FIQA does not aim to measure aesthetic or perceptual quality, but rather the suitability of a face image for recognition purposes~\cite{damer2021localfusion, best2018faceqnet}. This quality is influenced by a range of factors, including resolution, pose, occlusion, blur, compression, and illumination.
|
||||
Facial image quality assessment (FIQA) refers to the estimation of biometric utility from face images, typically in the context of face recognition, verification, or detection pipelines. Unlike generic no-reference IQA, FIQA does not aim to measure aesthetic or perceptual quality, but rather the suitability of a face image for recognition purposes~\cite{damer2021localfusion, best2018faceqnet}. This quality is influenced by a range of factors, including resolution, pose, occlusion, blur, compression, and illumination.
|
||||
|
||||
Traditional FIQA methods relied on handcrafted features such as sharpness, symmetry, or inter-eye distance~\cite{grother2003facequality}. Recent models leverage deep face embeddings extracted from recognition networks~\cite{terhorst2020serfiq, terhorst2022quality}. These models typically apply a regression or ranking loss to map features to quality scores correlated with recognition accuracy. For instance, FaceQnet~\cite{best2018faceqnet, hernandezortiz2019faceqnetv2} learns a regression model that predicts similarity-based utility from face embeddings. SER-FIQ~\cite{terhorst2020serfiq} estimates image quality by measuring the consistency of face embeddings under dropout-induced stochastic variation.
|
||||
Traditional FIQA methods relied on handcrafted features such as sharpness, symmetry, or inter-eye distance~\cite{grother2003facequality}. Recent models leverage deep face embeddings extracted from recognition networks~\cite{terhorst2020serfiq, terhorst2022quality}. These models typically apply a regression or ranking loss to map features to quality scores correlated with recognition accuracy.
|
||||
|
||||
FIQA is an inherently task-dependent quality problem. Unlike general-purpose IQA, it must account for the characteristics of the recognition model and dataset. Furthermore, FIQA methods often correlate poorly with perceptual quality metrics, as an image may appear visually high-quality but remain unsuitable for matching due to pose or occlusion. This motivates the need to explore perceptually grounded IQA models tailored to face data, and to investigate how traditional metrics can be adapted, fused, or compared against biometric-specific quality indicators.
|
||||
|
||||
\section{Steganography and Steganalysis}\label{sec:steganography}
|
||||
|
||||
Steganography is the practice of concealing information within other data. The goal is to embed secret messages in a way that is imperceptible to human observers, while steganalysis refers to the techniques used to detect such hidden information~\cite{steganography}. This field has evolved significantly with the advent of digital media and advanced compression algorithms, leading to a variety of embedding methods and detection strategies.
|
||||
\subsection{Steganography Techniques}\label{sec:steganography_techniques}
|
||||
Steganography techniques can be broadly categorized into spatial domain methods, frequency domain methods, and adaptive methods. Spatial domain methods directly manipulate pixel values to embed secret messages, often using least significant bit (LSB) substitution~\cite{steganography2017}. Frequency domain methods, such as discrete cosine transform (DCT) or discrete wavelet transform (DWT), embed information in the transformed coefficients of the image, making it more robust against compression and noise~\cite{zhang2017survey}. Adaptive methods dynamically adjust the embedding process based on the local characteristics of the image, improving imperceptibility and robustness~\cite{li2018adaptive}.
|
||||
\subsection{Steganalysis Techniques}\label{sec:steganalysis_techniques}
|
||||
Steganalysis techniques aim to detect the presence of hidden information in images. Traditional methods rely on statistical analysis of pixel values or transformed coefficients to identify anomalies indicative of steganography~\cite{fridrich2009steganography}. More recent approaches leverage machine learning and deep learning techniques to classify images as stego or cover based on learned features~\cite{cozzolino2015steganalysis, zhang2017survey}. These methods can achieve high detection accuracy, even against adaptive steganography techniques, by capturing subtle patterns that distinguish stego images from natural ones.
|
||||
\subsection{Steganography and Steganalysis in Facial Images}\label{sec:steganalysis_facial_images}
|
||||
Steganography and steganalysis in facial images present unique challenges and opportunities. Facial images are often subject to strict quality requirements for recognition tasks, making them sensitive to alterations~\cite{damer2021localfusion}. Steganographic techniques must balance imperceptibility with the need to embed sufficient information, while steganalysis methods must account for the specific characteristics of facial data, such as symmetry, texture, and lighting conditions~\cite{best2018faceqnet}.
|
||||
Recent research has explored the use of steganography in facial images for secure communication, watermarking, and privacy protection~\cite{damer2021localfusion}. Steganalysis techniques have also been adapted to detect hidden information in facial images, often using deep learning models trained on large datasets of stego and cover images~\cite{terhorst2020serfiq, terhorst2022quality}. These advancements highlight the need for specialized approaches that consider the unique properties of facial data while addressing the challenges of imperceptibility and robustness in steganographic applications.
|
||||
|
||||
\subsection{Printer-proof Steganography}\label{sec:printer_proof_steganography}
|
||||
Printer-proof steganography is a specialized form of steganography that focuses on embedding information in images while ensuring that the hidden data remains intact and detectable even after the image has been printed and scanned. This technique is particularly relevant in contexts where physical copies of images are distributed, such as in security documents, identification cards, or artworks.
|
||||
|
||||
The key challenge in printer-proof steganography is to design embedding methods that are robust against the distortions introduced by the printing and scanning processes. These distortions can include color shifts, resolution changes, and noise, which can significantly affect the visibility of the embedded information.
|
||||
|
||||
To achieve printer-proof steganography, several strategies can be employed:
|
||||
\begin{itemize}
|
||||
\item \textbf{Adaptive Embedding:} The embedding process can be adapted to the specific characteristics of the image and the expected distortions. This may involve analyzing the image content and selecting suitable regions for embedding that are less likely to be affected by printing artifacts.
|
||||
\item \textbf{Error Correction Codes:} Incorporating error correction codes can help recover the embedded information even if some parts are lost or distorted during printing and scanning. This is particularly important for maintaining the integrity of the hidden data.
|
||||
\item \textbf{Robust Feature Selection:} Selecting features that are less sensitive to distortions, such as texture or edge information, can improve the robustness of the embedded data. These features are often more resilient to changes introduced by printing processes.
|
||||
\item \textbf{Multi-layer Embedding:} Embedding information in multiple layers or channels of the image can enhance robustness. For example, using both luminance and chrominance channels can provide additional redundancy against distortions.
|
||||
\item \textbf{Testing and Validation:} Extensive testing with various printing and scanning conditions is crucial to ensure that the embedded information remains detectable. This may involve simulating different printing processes and evaluating the visibility and recoverability of the hidden data.
|
||||
\item \textbf{Perceptual Considerations:} Ensuring that the embedded information does not significantly degrade the visual quality of the image is essential. Techniques such as perceptual masking can be used to embed data in areas that are less noticeable to human observers, thereby maintaining the aesthetic quality of the image.
|
||||
\item \textbf{Machine Learning Approaches:} Recent advancements in machine learning can be leveraged to improve the robustness of printer-proof steganography. Deep learning models can learn to identify optimal embedding strategies and features that are resilient to printing distortions, enhancing the overall effectiveness of the steganographic process.
|
||||
\item \textbf{Evaluation Metrics:} Developing appropriate evaluation metrics to assess the effectiveness of printer-proof steganography is crucial. Metrics should consider both the imperceptibility of the embedded data and its robustness against printing and scanning distortions, providing a comprehensive assessment of the technique's performance.
|
||||
\item \textbf{Standardization:} Establishing standardized protocols for printer-proof steganography can facilitate comparisons between different techniques and promote best practices in the field. This can include guidelines for embedding methods, evaluation metrics, and testing procedures.
|
||||
\item \textbf{Applications:} Printer-proof steganography has various applications, including secure document distribution, watermarking for copyright protection, and embedding metadata in images for authentication purposes. Understanding the specific requirements of these applications can guide the development of effective steganographic techniques.
|
||||
\item \textbf{Ethical Considerations:} As with any steganographic technique, ethical considerations are paramount. Ensuring that printer-proof steganography is used responsibly and does not infringe on privacy or security rights is essential for maintaining trust in its applications.
|
||||
\end{itemize}
|
||||
@@ -1,69 +1,154 @@
|
||||
\section{Methodology}
|
||||
\chapter{Methodology}\label{chap:methodology}
|
||||
|
||||
This section describes the proposed hybrid Full-to-No-Reference (FR-to-NR) framework for Facial Image Quality Assessment (FIQA) in steganographically distorted images. The pipeline is divided into four stages:
|
||||
\section{Dataset}
|
||||
|
||||
\begin{itemize}
|
||||
\item Dataset construction and subjective human annotation.
|
||||
\item Analysis and fusion of Full-Reference IQA metrics to create a perceptually aligned quality estimator.
|
||||
\item Pseudo-MOS generation for weak supervision on unlabeled data.
|
||||
\item Training of a No-Reference regression model using deep features.
|
||||
\end{itemize}
|
||||
Our dataset is derived from the publically available Face Research Lab London~\cite{frll} (FRLL) set, comprising 102 adult faces, $1350 \times 1350$ pixels in full colour, frontal ICAO-compliant facial images. Self-reported age, gender and ethnicity are included. Attractiveness ratings (on a 1--7 scale from ``much less attractiveness than average'' to ``much more attractive than average'') for the neutral front faces from 2513 people (ages 17--90) are included as well.
|
||||
|
||||
This multistage approach allows for scalable perceptual quality prediction in scenarios where reference images or human ratings are unavailable.
|
||||
|
||||
\subsection{Dataset}
|
||||
|
||||
Our dataset is derived from the publically available Face Research Lab London (FRLL)~\cite{DeBruine2017} set, comprising 102 frontal ICAO-compliant facial images. Each image was encoded using four printer-proof steganographic methods, described ahead, each applied at nine different intensity levels, yielding a total of 3,672 distorted images.
|
||||
Each image was encoded using four printer-proof steganographic methods, described ahead, each applied at nine different intensity levels, yielding a total of 3,672 distorted images.
|
||||
|
||||
The dataset was partitioned into four subsets, as follows:
|
||||
|
||||
\begin{itemize}
|
||||
\item Labeled Set (15 identities, 540 images): a core set of demographically diverse subjects, shown in Fig.~\ref{fig:subdataset}, annotated with MOS through human evaluation.
|
||||
\item MOS set (15 identities, 540 images): a core set of demographically diverse subjects, shown in Fig.~\ref{fig:mos_set}, with subjective MOS annotations. It is split into:
|
||||
\begin{itemize}
|
||||
\item Training Subset (12 identities, 432 images): used to train the full-reference fusion model, regressing FR-IQA metrics to human MOS.\@
|
||||
\item Disjoint Test Subset (3 identities, 108 images): held out from the framework and are used solely for final results comparisons, simulating out-of-distribution generalization.
|
||||
\item MOS train set (12 identities): used to train the FR fusion model, regressing FR-IQA metrics to human MOS.\@
|
||||
\item MOS test set (3 identities): held out from the framework and used only for final evaluation.
|
||||
\end{itemize}
|
||||
\item Unlabeled Set (87 identities, 3,132 images): no subjective scores were collected for these images. Instead, pseudo-MOS labels were generated using the FR fusion model, enabling large-scale weak supervision.
|
||||
\item No-Reference (NR) Training Pool (99 identities, 3,564 images): Combines the 12 labeled identities and the 87 pseudo-labeled identities, and is used to train the NR regression model on deep features extracted from distorted images.
|
||||
\item Pseudo-MOS set (87 identities, 3,132 images): no subjective scores were collected for these images. Pseudo-MOS are generated for this set using the trained fusion model.
|
||||
\item NR train set: includes both the MOS train set and the pseudo-MOS set. It is used to train the NR regressor.
|
||||
\end{itemize}
|
||||
|
||||
\begin{figure}
|
||||
\centering
|
||||
\includegraphics[width=1\linewidth]{images/subdataset.png}
|
||||
\caption{Labeled set selected from the FRLL dataset.}\label{fig:subdataset}
|
||||
\begin{minipage}[t]{0.76\textwidth}
|
||||
\centering
|
||||
\includegraphics[width=\textwidth]{images/mos_train_set.pdf}\\
|
||||
\textbf{(a)} MOS train set % chktex 10
|
||||
\end{minipage}
|
||||
\hfill
|
||||
\begin{minipage}[t]{0.19\textwidth}
|
||||
\centering
|
||||
\includegraphics[width=\textwidth]{images/mos_test_set.pdf}\\
|
||||
\textbf{(b)} MOS test set % chktex 10
|
||||
\end{minipage}
|
||||
\caption{Reference images from the MOS set, comprising the selected subjects from the FRLL dataset.}\label{fig:mos_set}
|
||||
\end{figure}
|
||||
|
||||
The printer-proof steganography methods used were based on Generative Adversarial Networks (GANs)~\cite{gans2018} to encode and decode information, we can obtain various results depending on the method used:
|
||||
The printer-proof steganography methods used were based on Generative Adversarial Networks (GANs)~\cite{gans2018} to encode and decode information, illustrated in Fig.~\ref{fig:steganography}, we can obtain various results depending on the method used:
|
||||
|
||||
\begin{itemize}
|
||||
\item StegaStamp~\cite{stegastamp2020}: claims to be the first steganography model capable of decoding data from printed images. The authors show robust results in decoding data under physical transmission by developing novel strategies to add noise in the training process, printer noise simulation, and distortion for the training dataset.
|
||||
\item CodeFace~\cite{codeface2021}: encoder and decoder networks are trained using end-to-end GANs. It introduces a new security system for encoding and decoding facial images that are printed in common IDs and MRTDs.
|
||||
\item StegaStamp~\cite{stegastamp2020}: claims to be the first steganography model capable of decoding data from printed images. The authors show robust results in decoding data under physical transmission by adding printer noise in the training process.
|
||||
\item Code\,Face~\cite{codeface2021}: encoder and decoder networks are trained using end-to-end GANs. It introduces a new security system for encoding and decoding facial images that are printed in common IDs and MRTDs.
|
||||
\item RiemStega~\cite{cruz2025riemstega}: proposes a new loss function that extends the loss function based on the $L_2$ distance between images to the Riemannian manifold of symmetric and positive definite matrices.
|
||||
\item StampOne~\cite{stampone2023}: focuses on high-level robust steganography, such as~\cite{codeface2021, stegastamp2020}, striking a balance between high-quality encoded images and decoding accuracy. It mitigates distortion-related issues like JPEG compression, camera sensors and printer's Gaussian noise by incorporating gradient transform, wavelet transform, and Depthwise~\cite{tay2022efficient} to normalize and balance frequencies of the inputs.
|
||||
\item StampOne~\cite{stampone2024}: focuses on high-level robust steganography, such as~\cite{codeface2021, stegastamp2020}, it balances between high-quality encoded images and decoding accuracy. It mitigates distortion-related issues like JPEG compression, camera sensors and printer's Gaussian noise by incorporating gradient transform and wavelet transform to normalize and balance frequencies of the inputs.
|
||||
\end{itemize}
|
||||
|
||||
Each image in our dataset was evaluated approximately 30 times by human observers, providing a robust MOS dataset.
|
||||
\begin{figure}[ht]
|
||||
\centering
|
||||
\begin{minipage}[t]{0.2\textwidth}
|
||||
\centering
|
||||
\includegraphics[width=\textwidth]{images/005_StegaStamp_1.4.jpg}\\
|
||||
\textbf{(a)} StegaStamp
|
||||
\end{minipage}
|
||||
\hfill
|
||||
\begin{minipage}[t]{0.2\textwidth}
|
||||
\centering
|
||||
\includegraphics[width=\textwidth]{images/005_CodeFace_1.4.jpg}\\
|
||||
\textbf{(b)} Code\,Face
|
||||
\end{minipage}
|
||||
\hfill
|
||||
\begin{minipage}[t]{0.2\textwidth}
|
||||
\centering
|
||||
\includegraphics[width=\textwidth]{images/005_RiemStega_1.4.jpg}\\
|
||||
\textbf{(c)} RiemStega
|
||||
\end{minipage}
|
||||
\hfill
|
||||
\begin{minipage}[t]{0.2\textwidth}
|
||||
\centering
|
||||
\includegraphics[width=\textwidth]{images/005_StampOne_1.4.jpg}\\
|
||||
\textbf{(d)} StampOne
|
||||
\end{minipage}
|
||||
\caption{Steganographically distorted facial images from each method.}\label{fig:steganography}
|
||||
\end{figure}
|
||||
|
||||
We followed ITU-R BT.500--15~\cite{ITU-R-BT500} recommendation, and adopted the Single Stimulus method. Around 200 different observers were carefully instructed on how to perform the test session, the average duration of the session was 22 minutes, and the rounded number of tests in each session was 70. Resulting in over 14,000 evaluations.
|
||||
|
||||
To conduct the sessions we created a webapp in Django, seen in Fig.~\ref{fig:platform}, where the observers were asked to evaluate each image on a scale from 1 to 100 using a slider bar, with no time limit. The rating scale was divided into five categorical levels: scores from 1 to 25 were classified as Bad, 26 to 50 as Poor, 51 to 75 as Fair, 76 to 99 as Good, and a score of 100 as Excellent.
|
||||
We followed the ITU-R BT.500--15~\cite{ITU-R-BT500} recommendation and adopted the Single Stimulus (SS) method. The test was implemented using a custom Django web application seen in Fig.~\ref{fig:webapp}. Prior to the test session, participants signed an informed consent form and filled out a registration form providing demographic and environmental information such as age, gender, education, country of origin and ethnicity, and others. Each image was shown individually, with no time limit. Ratings were submitted using a labeled slider, and automatic saving ensured session robustness.
|
||||
|
||||
Each image in the MOS set was evaluated approximately 30 times by human observers, resulting in over 14,000 ratings. We had around 200 participants, each session lasted about 22 minutes and included roughly 70 evaluations. Following the session, outlier observers were identified and removed using both Kurtosis-based and correlation-based post-screening methods described in ITU-R BT.500--15~\cite{ITU-R-BT500}, resulting in the exclusion of four participants.
|
||||
|
||||
\begin{figure}
|
||||
\centering
|
||||
\includegraphics[width=0.5\linewidth]{images/webapp.png}
|
||||
\caption{Snippet of the custom webapp platform used to access overall image quality.}\label{fig:platform}
|
||||
\includegraphics[width=0.32\textwidth]{images/webapp_test.png}
|
||||
\caption{Django-based webapp created for the Single Stimulus test.}\label{fig:webapp}
|
||||
\end{figure}
|
||||
|
||||
To address this, we propose a two-stage hybrid pipeline that first builds a FR quality estimator supervised by MOS, and then extends this supervision to a NR model via pseudo-MOS learning.
|
||||
\section{Debiasing of Subjective Scores}
|
||||
|
||||
\subsection{Full-Reference Analysis and Fusion}
|
||||
To correct for demographic bias in the subjective scores, we followed a procedure inspired by prior work on bias correction in perceptual tasks~\cite{clapes2018apparent}, where we applied a residualization method based on linear modeling. An ordinary least squares (OLS) regression was fit to the MOS values, using observer and image attributes, and their pairwise interactions as categorical predictors. The fitted bias components were subtracted from the original scores, and the residuals were mean-centered to preserve the global score distribution. As shown in Table~\ref{tab:anova}, several factors exhibit statistically significant effects on the MOS prior to residualization, notably observer and subject ethnicity. After applying the residualization procedure, these effects disappear, as confirmed by an ANOVA test showing no significant impact from any individual factor. The corrected MOS labels are then used as ground truth in all supervised stages of the pipeline to ensure fairness and reduce the influence of socially conditioned priors.
|
||||
|
||||
We compute 41 FR-IQA scores for each distorted image in the MOS-labeled subset. To identify which metrics align best with human perception, we calculate both the Pearson Linear Correlation Coefficient (PLCC) and the Spearman Rank-Order Correlation Coefficient (SRCC)~\cite{plcc_srcc} between each metric and the human MOS.\@ This analysis serves to rank the metrics and select the top-$k$ most perceptually relevant.
|
||||
\begin{table}
|
||||
\centering
|
||||
\caption{ANOVA~\cite{ross2017one} results for observer and image attributes. Before debiasing, several factors show statistically significant effects on MOS, p-value $< 0.05$.\@ After residualization, all main effects show no significant impact, confirming the effectiveness of the debiasing procedure.}\label{tab:anova}
|
||||
\begin{tabular}{lcc}
|
||||
\hline % chktex 44
|
||||
Factor & p-value & p-value (residualized) \\
|
||||
\hline % chktex 44
|
||||
Observer gender & 0.022 & 0.9930 \\
|
||||
Observer ethnicity & $8.44 \times 10^{-4}$ & 1 \\
|
||||
Subject gender & $1.60 \times 10^{-3}$ & 0.9722 \\
|
||||
Subject ethnicity & $7.36 \times 10^{-3}$ & 1 \\
|
||||
Observer gender $\times$ Subject gender & 0.6417 & 0.6417 \\
|
||||
Observer ethnicity $\times$ Subject ethnicity & 0.0582 & 0.0582 \\
|
||||
\hline % chktex 44
|
||||
\end{tabular}
|
||||
\end{table}
|
||||
|
||||
\subsection{Pseudo-MOS Generation via FR-IQA Fusion}
|
||||
\section{Correlation of FR-IQA Metrics with Human Perception}
|
||||
|
||||
The selected top-$k$ IQA metrics are standardized and used as input features for supervised regression models trained to approximate the human MOS.\@ We evaluate Support Vector Regression~\cite{svr}, Random Forest~\cite{randomforest}, XGBoost~\cite{xgboost}, and LightGBM~\cite{lightgbm} as candidate fusion models. Random Forest consistently achieved the highest PLCC and SRCC on the validation set for $k=5$, and was selected as the fusion model. This trained regressor is then applied to the unlabeled portion of the dataset (3,132 distorted images), generating pseudo-MOS scores that serve as proxy ground-truth labels.
|
||||
We compute 40 FR-IQA scores for each distorted image in the dataset and compare them against the corresponding MOS, as seen in Fig.~\ref{fig:mos_vs_iqa}. Several metrics exhibit strong linear trends with MOS, while others are poorly aligned or even negatively correlated. For a detailed description of these metrics, we refer the reader to~\cite{shahrukh2019survey}.
|
||||
|
||||
\subsection{NR Regression Model}
|
||||
|
||||
To enable NR quality prediction, we extract deep features from each distorted image using a ResNet-18~\cite{resnet} model pretrained on ImageNet. These feature vectors are then used to train a regression model, again using Random Forest, tasked with predicting the pseudo-MOS labels obtained from the FR fusion step. The final model performs quality assessment using only the distorted input image, without requiring access to a reference image, thereby enabling NR-IQA in real-world scenarios.
|
||||
|
||||
\begin{figure}
|
||||
\centering
|
||||
\includegraphics[width=0.90\linewidth]{images/mos_vs_iqa_grid.pdf}
|
||||
\caption{Scatter plots illustrating the relationship between MOS and 40 individual full-reference IQA metrics. The red line represents a smoothed local trend curve.}\label{fig:mos_vs_iqa}
|
||||
\end{figure}
|
||||
|
||||
\section{Fusion of FR-IQA Metrics for Pseudo-MOS Estimation}
|
||||
|
||||
To identify which metrics align best with human perception, we compute both the Pearson Linear Correlation Coefficient (PLCC) and the Spearman Rank-Order Correlation Coefficient (SRCC)~\cite{plcc-srcc} which respectively quantify the linearity and monotonicity of the relationship between metric scores and MOS.\@ To determine the appropriate number of metrics to retain for fusion, we applied Singular Value Decomposition (SVD) and the Picard criterion~\cite{hansen1998picard}. Metrics are first ranked by the average of their PLCC and SRCC with MOS.\@ After normalizing the feature matrix, SVD revealed that six components capture 95\% of the total variance, as shown in Fig.~\ref{fig:svd_analysis}a, indicating an optimal dimensionality of $k=6$.
|
||||
|
||||
To validate this truncation point, we examined the Picard plot in Fig.~\ref{fig:svd_analysis}b, which compares singular values with the target projections. The stable ratio in the tail confirms that six components provide a good balance between expressiveness and stability. This supports a compact, informative subset of FR-IQA metrics.
|
||||
|
||||
\begin{figure}[ht]
|
||||
\centering
|
||||
\begin{minipage}[t]{0.48\textwidth}
|
||||
\centering
|
||||
\includegraphics[width=\linewidth]{images/variance.pdf}
|
||||
\textbf{(a)} Cumulative variance explained by SVD components.
|
||||
\end{minipage}
|
||||
\hfill
|
||||
\begin{minipage}[t]{0.48\textwidth}
|
||||
\centering
|
||||
\includegraphics[width=\linewidth]{images/picard.pdf}
|
||||
\textbf{(b)} Magnitude of singular values and projected response.
|
||||
\end{minipage}
|
||||
\caption{SVD-based analysis of the FR metric space. The cumulative explained variance (a) guides the choice of dimensionality, while the Picard criterion (b) illustrates stability near $k=6$.}\label{fig:svd_analysis}
|
||||
\end{figure}
|
||||
|
||||
After selecting the top $k = 6$ FR-IQA metrics, we trained a diverse set of supervised regressors to map these features to subjective MOS scores. The models included both linear and non-linear types:
|
||||
|
||||
\begin{itemize}
|
||||
\item Linear models: Linear Regression~\cite{linearregression}, Ridge Regression~\cite{ridgeregression}, Bayesian Ridge~\cite{bayesianridge}, ElasticNet~\cite{elasticnet}.
|
||||
\item Kernel-based: Support Vector Regression~\cite{svr} (SVR).
|
||||
\item Ensembles: Random Forest~\cite{randomforest}, Extra Trees~\cite{ensembles}, Gradient Boosting~\cite{gradboosting}, HistGradientBoosting~\cite{histboost}.
|
||||
\item Boosted Trees: XGBoost\cite{xgboost}, LightGBM~\cite{lightgbm}, CatBoost~\cite{catboost}.
|
||||
\end{itemize}
|
||||
|
||||
Each regressor was trained using five-fold cross-validation with an exhaustive grid search over predefined hyperparameter spaces. The best model, CatBoost, optimal configuration was: depth = 8, iterations = 500, learning rate = 0.05, and $L_2$ regularization = 1. This trained regressor is then applied to the unlabeled portion of the dataset (3,132 distorted images), generating pseudo-MOS.\@
|
||||
|
||||
\section{Training a No-Reference IQA Model from Pseudo-MOS}
|
||||
|
||||
To enable NR quality prediction, we train a deep regression model end-to-end using pseudo-MOS scores as targets. The architecture is based on a ResNet-18 backbone~\cite{resnet} pretrained on ImageNet~\cite{imagenet}, with its final classification layer replaced by a lightweight multi-layer perceptron (MLP) regressor~\cite{bayesianridge}. All layers are fine-tuned during training to learn perceptual quality representations specific to our task. The training set consists of distorted facial images paired with either pseudo-MOS, from the FR fusion, or real MOS labels, when available. The model is optimized using MSE and evaluated on the, disjoint, MOS test set of labeled images. Once trained, the model infers image quality solely from the distorted input, enabling NR assessment aligned with human perception.
|
||||
|
||||
|
||||
@@ -0,0 +1,72 @@
|
||||
\section{Results}
|
||||
|
||||
\subsection{Full-Reference Fusion Metric Performance}
|
||||
|
||||
|
||||
To interpret feature contributions, we used SHAP~\cite{shap} (SHapley Additive exPlanations) values derived from CatBoost's internal structure. SHAP values quantify how much a feature pushes the model's output away from the expected value. As shown in Fig.~\ref{fig:shap_summary}, MS-SSIM~\cite{wang2003multiscale} (Multiscale SSIM) and UQI~\cite{wang2004ssim} (Universal Quality Index) had the largest positive impact on predictions, while PSNR-B~\cite{ma2011psnr}, VIF\cite{sheikh2006image}, (PSNR-Blocking), PSNR~\cite{pnsr2003} and SNR~\cite{gonzalez2002digital} (Signal-to-Noise Ratio) contributed with moderate influence. The color encoding further highlights how high and low feature values affect the model output.
|
||||
|
||||
\begin{figure}
|
||||
\centering
|
||||
\includegraphics[width=0.7\linewidth]{images/shap_summary.png}
|
||||
\caption{SHAP summary plot for $k=6$, generated from the best CatBoost model.}\label{fig:shap_summary}
|
||||
\end{figure}
|
||||
|
||||
When comparing the fusion metric with the individual FR metrics, Table~\ref{tab:fr_model_score} shows that the fusion metric outperformed all individual metrics in terms of PLCC, SRCC, MSE and MAE.\@ This demonstrates the effectiveness of our approach in combining multiple FR metrics to improve overall performance.
|
||||
|
||||
\begin{table}
|
||||
\centering
|
||||
\caption{Performance of our Fusion metric and the selected FR-IQA metrics. Higher PLCC and SRCC indicates better correlation with MOS.\@ Lower MSE and MAE indicate more accurate quality estimates.}\label{tab:fr_model_score}
|
||||
\begin{tabular}{lcccc}
|
||||
\hline % chktex 44
|
||||
\textbf{Metric} & \textbf{PLCC} & \textbf{SRCC} & \textbf{MSE} & \textbf{MAE} \\
|
||||
\hline % chktex 44
|
||||
Fusion (CatBoost) & \textbf{0.8881} & \textbf{0.8893} & \textbf{65.07} & \textbf{6.160} \\
|
||||
MS-SSIM & 0.7712 & 0.8489 & 2542 & 47.27 \\
|
||||
PSNR & 0.8009 & 0.8132 & 420.7 & 16.57 \\
|
||||
PSNR-B & 0.7996 & 0.8126 & 434.8 & 16.84 \\
|
||||
SNR & 0.7931 & 0.8047 & 493.9 & 18.08 \\
|
||||
VIF & 0.7723 & 0.7671 & 2584 & 47.75 \\
|
||||
UQI & 0.6866 & 0.8085 & 2540 & 47.24 \\
|
||||
\hline % chktex 44
|
||||
\end{tabular}
|
||||
\end{table}
|
||||
|
||||
\subsection{No-Reference Regression Model Performance}
|
||||
|
||||
We refer to our NR-IQA model as pMOS-Face (pseudo-MOS for Face), reflecting its use of pseudo-MOS labels generated from the FR fusion model and its evaluation on faces. This framework can be adapted to other datasets, provided that a small set of images with human labels is available for training the FR fusion model. Fig.~\ref{fig:nr-iqa-metric} shows two evaluation scenarios: in Fig.~\ref{fig:nr-iqa-metric}(a), the model's predictions are compared against the pseudo and ground-truth MOS used during training, yielding a PLCC of 0.9285, SRCC of 0.9345, MSE of 120.2, and MAE of 9.158. Fig.~\ref{fig:nr-iqa-metric}(b) shows the predictions compared against the MOS test set, resulting in a PLCC of 0.9679, SRCC of 0.9691 and MSE of 35.34 and MAE of 4.743. These results confirm both generalization to unseen human labels and alignment with the pseudo-supervision used for training. % chktex 36
|
||||
|
||||
\begin{figure}[ht]
|
||||
\centering
|
||||
\begin{minipage}[t]{0.48\textwidth}
|
||||
\centering
|
||||
\includegraphics[width=\linewidth]{images/predictions_train.pdf}
|
||||
\textbf{(a)} Training plot.\@
|
||||
\end{minipage}
|
||||
\hfill
|
||||
\begin{minipage}[t]{0.48\textwidth}
|
||||
\centering
|
||||
\includegraphics[width=\linewidth]{images/predictions_test.pdf}
|
||||
\textbf{(b)} Test plot.\@
|
||||
\end{minipage}
|
||||
\caption{Evaluation of our NR-IQA model. Panel (a) shows performance on the training set with pseudo and ground-truth MOS;\@ panel (b) shows performance on the disjoint test set with ground-truth MOS.}\label{fig:nr-iqa-metric}
|
||||
\end{figure}
|
||||
|
||||
The results indicate that our model is more effective in predicting perceptual quality than classical NR-IQA metrics such as NIQE~\cite{mittal2013making} and PIQE~\cite{piqe2016}, as well as task-specific approaches like SER-FIQ~\cite{terhorst2020serfiq} and MagFace~\cite{meng2021magface}. This highlights the robustness of our weakly supervised strategy for NR-IQA on steganographically degraded facial images. Quantitative results are reported in Table~\ref{tab:nr_scores}.
|
||||
|
||||
\begin{table}
|
||||
\centering
|
||||
\caption{Performance of our pMOS-Face compared to standard NR-IQA baselines.}\label{tab:nr_scores}
|
||||
\begin{tabular}{lcccc}
|
||||
\hline % chktex 44
|
||||
\textbf{Metric} & \textbf{PLCC} & \textbf{SRCC} & \textbf{MSE} & \textbf{MAE} \\
|
||||
\hline % chktex 44
|
||||
pMOS-Face (ours) & \textbf{0.9285} & \textbf{0.9345} & \textbf{120.6} & \textbf{9.158} \\
|
||||
NIQE & 0.7536 & 0.7431 & 6859 & 82.62 \\
|
||||
PIQE & 0.2993 & 0.3114 & 3297 & 57.05 \\
|
||||
SER-FIQ & -0.1648 & -0.1542 & 123.5 & 9.230 \\
|
||||
MagFace & -0.6095 & -0.6362 & 4437 & 66.24 \\
|
||||
\hline % chktex 44
|
||||
\end{tabular}
|
||||
\end{table}
|
||||
|
||||
When considering a more generalized use, where observer bias is not accounted for, our NR-IQA model shows a major improvement over the baselines. This is particularly relevant for task specific applications, where the model can be trained on a small set of images with human labels and then applied to larger datasets without the need for additional supervision. This approach allows for a more scalable and efficient solution not only for FIQA but also for other domains where reference images are not available.
|
||||
@@ -0,0 +1,5 @@
|
||||
\section{Conclusion and Future Work}
|
||||
|
||||
We proposed a Full-to-No-Reference framework for FIQA that predicts image quality in the absence of reference images by leveraging a pseudo-MOS supervision strategy. Our method first trains a FR fusion model to regress human perceptual judgments on a labeled subset (10\% of the dataset), generating pseudo-MOS labels for a larger unlabeled dataset. These forged labels are then used to train a deep NR regressor, enabling quality prediction from distorted images alone. This two-stage pipeline effectively bridges the gap between fully supervised FR-IQA and reference-free NR-IQA approaches.
|
||||
|
||||
Beyond the development of our NR IQA metric, the proposed framework offers a flexible foundation for constructing a variety of task-specific models. By enabling scalable, perceptually grounded supervision with limited ground-truth annotations, our approach can facilitate quality-aware training in applications such as GANs, forensic imaging, and domain-adapted biometric pipelines.
|
||||
@@ -1,75 +0,0 @@
|
||||
\chapter{Development of the Full-Reference Metric}
|
||||
|
||||
\section{Introduction}
|
||||
|
||||
This chapter outlines the development of a Full-Reference Fusion Metric (FRFM), a novel IQA metric designed to align with human perception. By synthesizing the strengths of multiple objective metrics, the FRFM bridges the gap between subjective Mean Opinion Scores (MOS) and computational evaluations. The chapter details the selection, fusion, and validation processes that underpin the metric's development.
|
||||
|
||||
\section{Metric Selection}
|
||||
|
||||
The first step in developing the FRFM involves identifying metrics that exhibit high correlation with MOS data. A comprehensive analysis of 50 metrics, including traditional, no-reference, and learning-based methods, was performed. The metrics with the strongest correlations were shortlisted for the fusion process.
|
||||
|
||||
\subsection{Correlation Analysis}
|
||||
|
||||
Metrics were evaluated using Pearson, Spearman, and Kendall’s Tau correlation coefficients. The analysis revealed the following metrics as the most aligned with MOS:
|
||||
\begin{itemize}
|
||||
\item Structural Similarity Index (SSIM) (Wang et al., 2004)
|
||||
\item Learned Perceptual Image Patch Similarity (LPIPS) (Zhang et al., 2018)
|
||||
\item Visual Information Fidelity (VIF) (Sheikh and Bovik, 2006)
|
||||
\item Perceptual Adversarial Similarity Score (PASS) (Liu et al., 2021)
|
||||
\end{itemize}
|
||||
|
||||
These metrics were selected for their complementary strengths:
|
||||
\begin{itemize}
|
||||
\item SSIM captures structural similarities, making it effective for standard distortions.
|
||||
\item LPIPS leverages deep feature representations, aligning well with human perception of complex artifacts.
|
||||
\item VIF quantifies the preservation of visual information.
|
||||
\item PASS excels at detecting perceptual changes in steganographic and adversarial contexts.
|
||||
\end{itemize}
|
||||
|
||||
\section{Fusion Methodology}
|
||||
|
||||
The selected metrics were integrated into a unified framework using a weighted fusion approach. The methodology ensures that the FRFM captures diverse aspects of image quality while maintaining alignment with human evaluations.
|
||||
|
||||
\subsection{Normalization}
|
||||
|
||||
To ensure comparability, the selected metrics were normalized to a common scale using min-max normalization:
|
||||
\[
|
||||
M_i^{\text{norm}} = \frac{M_i - M_{\text{min}}}{M_{\text{max}} - M_{\text{min}}}
|
||||
\]
|
||||
where \(M_i\) is the metric score, and \(M_{\text{min}}\) and \(M_{\text{max}}\) are the minimum and maximum scores, respectively.
|
||||
|
||||
\subsection{Weight Assignment}
|
||||
|
||||
Weights were assigned to each metric based on its correlation coefficient with MOS data:
|
||||
\[
|
||||
w_i = \frac{\rho_i}{\sum_{j=1}^{n} \rho_j}
|
||||
\]
|
||||
where \(w_i\) is the weight for metric \(i\), and \(\rho_i\) is its correlation coefficient.
|
||||
|
||||
\subsection{Fusion Equation}
|
||||
|
||||
The overall quality score \(Q\) was computed as a weighted sum of the normalized metric scores:
|
||||
\[
|
||||
Q = \sum_{i=1}^{n} w_i \cdot M_i^{\text{norm}}
|
||||
\]
|
||||
This equation ensures that metrics with higher correlations contribute more to the final quality score.
|
||||
|
||||
\section{Validation of the FRFM}
|
||||
|
||||
The FRFM was validated using unseen images from the dataset. The validation process involved:
|
||||
\begin{itemize}
|
||||
\item \textbf{Correlation with MOS:} The FRFM’s scores were compared with MOS values to assess alignment.
|
||||
\item \textbf{Comparison with Baseline Metrics:} The FRFM was benchmarked against individual metrics such as SSIM and LPIPS.
|
||||
\item \textbf{Evaluation on Steganography:} The metric's performance was tested on steganography-encoded images, where traditional metrics often fail.
|
||||
\end{itemize}
|
||||
|
||||
\subsection{Performance Metrics}
|
||||
|
||||
The validation included:
|
||||
\begin{itemize}
|
||||
\item Pearson and Spearman correlations to measure linear and rank-based relationships with MOS.
|
||||
\item Root Mean Squared Error (RMSE) to evaluate prediction accuracy.
|
||||
\item Visual examples to qualitatively assess the metric's ability to detect perceptual artifacts.
|
||||
\end{itemize}
|
||||
|
||||
The results demonstrated that the FRFM outperformed traditional metrics, particularly in scenarios involving subtle distortions and steganography. The next chapter discusses the extension of the FRFM to a No-Reference Metric (NRM) for real-world applications.
|
||||
@@ -1,62 +0,0 @@
|
||||
\chapter{No-Reference Metric Design}
|
||||
|
||||
\section{Introduction}
|
||||
|
||||
While Full-Reference metrics like the FRFM require a pristine reference image, real-world applications often lack such references. This limitation necessitates the development of No-Reference Metrics (NRMs), which assess image quality directly from distorted images. This chapter outlines the design and implementation of an NRM based on the FRFM, leveraging neural networks to generalize the metric to reference-free scenarios.
|
||||
|
||||
\section{Training Framework}
|
||||
|
||||
The NRM is developed using the FRFM scores as ground truth, enabling the model to learn perceptual quality evaluation without relying on reference images.
|
||||
|
||||
\subsection{Dataset Preparation}
|
||||
|
||||
The dataset for training the NRM consists of:
|
||||
\begin{itemize}
|
||||
\item \textbf{Input:} Steganography-encoded images with diverse distortions.
|
||||
\item \textbf{Target:} FRFM scores computed for each image.
|
||||
\end{itemize}
|
||||
Data augmentation techniques, such as random cropping, scaling, and color adjustments, are applied to increase dataset diversity and improve model robustness.
|
||||
|
||||
\subsection{Model Architecture}
|
||||
|
||||
The NRM employs a convolutional neural network (CNN) architecture, optimized for image quality assessment tasks:
|
||||
\begin{itemize}
|
||||
\item \textbf{Input Layer:} Accepts distorted images resized to a fixed resolution.
|
||||
\item \textbf{Convolutional Layers:} Extract low- and high-level features, focusing on distortions in key regions.
|
||||
\item \textbf{Fully Connected Layers:} Combine extracted features to predict a single quality score.
|
||||
\item \textbf{Output Layer:} Produces a scalar value representing the predicted quality score.
|
||||
\end{itemize}
|
||||
The model is implemented using PyTorch, with hyperparameters fine-tuned through cross-validation.
|
||||
|
||||
\subsection{Loss Function}
|
||||
|
||||
The model is trained using a regression loss function to minimize the difference between predicted and ground truth FRFM scores:
|
||||
\[
|
||||
\mathcal{L} = \frac{1}{N} \sum_{i=1}^{N} (Q_i^{\text{predicted}} - Q_i^{\text{true}})^2
|
||||
\]
|
||||
where \(Q_i^{\text{predicted}}\) is the predicted score and \(Q_i^{\text{true}}\) is the FRFM score for the \(i\)-th image.
|
||||
|
||||
\section{Validation and Testing}
|
||||
|
||||
The NRM is validated on a held-out dataset to ensure its generalizability and robustness.
|
||||
|
||||
\subsection{Evaluation Metrics}
|
||||
|
||||
The following metrics are used to evaluate the NRM’s performance:
|
||||
\begin{itemize}
|
||||
\item \textbf{Correlation Coefficients:} Pearson and Spearman correlations between predicted scores and MOS values.
|
||||
\item \textbf{Root Mean Squared Error (RMSE):} Measures the accuracy of the predictions.
|
||||
\item \textbf{Rank Consistency:} Assesses the NRM’s ability to preserve relative rankings of image quality.
|
||||
\end{itemize}
|
||||
|
||||
\subsection{Qualitative Evaluation}
|
||||
|
||||
Visual examples are used to assess the NRM’s ability to detect perceptual artifacts. Examples include:
|
||||
\begin{itemize}
|
||||
\item Images with localized distortions, such as artifacts in facial regions.
|
||||
\item Steganography-encoded images with subtle embedding artifacts.
|
||||
\end{itemize}
|
||||
|
||||
The NRM demonstrates strong alignment with MOS values, achieving high correlation and low error rates. Its ability to detect perceptual distortions without reference images makes it suitable for real-world applications, including facial image quality assessment and secure communications.
|
||||
|
||||
The next chapter presents the results of the experiments, comparing the performance of the FRFM and NRM against baseline metrics and subjective evaluations.
|
||||
@@ -1,105 +0,0 @@
|
||||
\chapter{Results and Discussion}
|
||||
|
||||
\section{Introduction}
|
||||
|
||||
This chapter presents the experimental results of the Full-Reference Fusion Metric (FRFM) and No-Reference Metric (NRM), evaluating their performance against traditional metrics and subjective Mean Opinion Scores (MOS). The results are analyzed in terms of correlation with subjective evaluations, robustness to distortions, and applicability to steganography-encoded images. Key insights and implications are discussed, highlighting the strengths and limitations of the proposed metrics.
|
||||
|
||||
\section{Performance Evaluation of FRFM}
|
||||
|
||||
\subsection{Correlation with MOS}
|
||||
|
||||
The FRFM exhibited strong correlations with subjective MOS values across all images in the dataset. Table \ref{tab:frfm_correlation} summarizes the correlation coefficients:
|
||||
\[
|
||||
\begin{array}{|c|c|c|c|}
|
||||
\hline
|
||||
\textbf{Metric} & \textbf{Pearson} & \textbf{Spearman} & \textbf{Kendall's Tau} \\
|
||||
\hline
|
||||
\textbf{FRFM} & 0.92 & 0.89 & 0.85 \\
|
||||
\textbf{SSIM} & 0.75 & 0.71 & 0.68 \\
|
||||
\textbf{LPIPS} & 0.88 & 0.84 & 0.81 \\
|
||||
\textbf{VIF} & 0.82 & 0.79 & 0.76 \\
|
||||
\hline
|
||||
\end{array}\label{tab:frfm_correlation}
|
||||
\]
|
||||
The FRFM outperformed individual metrics, demonstrating its effectiveness in aligning with human perception.
|
||||
|
||||
\subsection{Performance on Steganography-Encoded Images}
|
||||
|
||||
The FRFM's ability to evaluate steganography-encoded images was tested by comparing its scores against MOS for different embedding thresholds and methods. Results showed that the FRFM maintained high correlations even at subtle distortion levels, outperforming traditional metrics like PSNR and SSIM.
|
||||
|
||||
\subsection{Visual Analysis}
|
||||
|
||||
Qualitative examples illustrate the FRFM's sensitivity to perceptual distortions. Figure ref fig shows a comparison between FRFM and baseline metrics for an image with localized artifacts.
|
||||
|
||||
%\begin{figure}[h]
|
||||
% \centering
|
||||
% \includegraphics[width=0.8\textwidth]{frfm_visual_example.png}
|
||||
% \caption{Visual comparison of FRFM and baseline metrics for an image with perceptual distortions.}
|
||||
% \label{fig:frfm_visual}
|
||||
%\end{figure}
|
||||
|
||||
(insert image: Visual comparison of FRFM and baseline metrics for an image with perceptual distortions.)
|
||||
|
||||
\section{Performance Evaluation of NRM}
|
||||
|
||||
\subsection{Correlation with MOS}
|
||||
|
||||
The NRM achieved strong alignment with subjective evaluations, as summarized in Table \ref{tab:nrm_correlation}:
|
||||
\[
|
||||
\begin{array}{|c|c|c|c|}
|
||||
\hline
|
||||
\textbf{Metric} & \textbf{Pearson} & \textbf{Spearman} & \textbf{Kendall's Tau} \\
|
||||
\hline
|
||||
\textbf{NRM} & 0.88 & 0.85 & 0.81 \\
|
||||
\textbf{BRISQUE} & 0.73 & 0.69 & 0.65 \\
|
||||
\textbf{NIQE} & 0.68 & 0.64 & 0.60 \\
|
||||
\textbf{PASS} & 0.82 & 0.79 & 0.76 \\
|
||||
\hline
|
||||
\end{array}\label{tab:nrm_correlation}
|
||||
\]
|
||||
|
||||
\subsection{Generalization Across Distortions}
|
||||
|
||||
The NRM demonstrated robustness across different types of distortions, including steganographic artifacts and common image degradations. Its performance was consistent across diverse embedding thresholds, indicating its adaptability to real-world scenarios.
|
||||
|
||||
\subsection{Qualitative Evaluation}
|
||||
|
||||
The NRM's ability to detect perceptual distortions was validated through visual examples. Figure ref to fig highlights the NRM's sensitivity to distortions in key facial regions, such as the eyes and mouth.
|
||||
|
||||
%\begin{figure}[h]
|
||||
% \centering
|
||||
% \includegraphics[width=0.8\textwidth]{nrm_visual_example.png}
|
||||
% \caption{Visual analysis of NRM's performance on facial images with localized distortions.}
|
||||
% \label{fig:nrm_visual}
|
||||
%\end{figure}
|
||||
|
||||
(insert image: Visual analysis of NRM's performance on facial images with localized distortions.)
|
||||
|
||||
\section{Comparison Between FRFM and NRM}
|
||||
|
||||
A comparison between the FRFM and NRM revealed that:
|
||||
\begin{itemize}
|
||||
\item The FRFM provides higher accuracy in controlled settings with reference images.
|
||||
\item The NRM excels in real-world applications where reference images are unavailable.
|
||||
\item Both metrics outperformed traditional methods in terms of correlation with MOS and robustness to distortions.
|
||||
\end{itemize}
|
||||
|
||||
\section{Discussion}
|
||||
|
||||
\subsection{Key Insights}
|
||||
|
||||
The results demonstrate that:
|
||||
\begin{itemize}
|
||||
\item Combining multiple metrics into a fusion framework significantly improves alignment with human perception.
|
||||
\item Neural network-based NR metrics can generalize well to unseen distortions and datasets.
|
||||
\item The proposed metrics are particularly effective for steganography-encoded images, addressing limitations of traditional approaches.
|
||||
\end{itemize}
|
||||
|
||||
\subsection{Limitations and Future Work}
|
||||
|
||||
Despite their strengths, the proposed metrics have limitations:
|
||||
\begin{itemize}
|
||||
\item The FRFM's reliance on reference images limits its applicability in real-world scenarios.
|
||||
\item The NRM requires extensive training data, which may not be available for all applications.
|
||||
\item Future work could explore hybrid approaches that integrate reference-based and reference-free methodologies.
|
||||
\end{itemize}
|
||||
@@ -1,42 +0,0 @@
|
||||
\chapter{Conclusion and Future Work}
|
||||
|
||||
\section{Conclusion}
|
||||
|
||||
This thesis addressed the challenge of aligning objective Image Quality Assessment (IQA) metrics with human perception, particularly in the context of facial images and steganography-encoded distortions. The research was driven by the need for metrics that capture subtle, perceptually significant artifacts while maintaining computational feasibility.
|
||||
|
||||
The primary contributions of this work include:
|
||||
\begin{itemize}
|
||||
\item Development of the Full-Reference Fusion Metric (FRFM), which integrates multiple highly correlated metrics into a unified framework, achieving superior alignment with subjective evaluations.
|
||||
\item Design of the No-Reference Metric (NRM), leveraging neural networks to generalize quality assessment to scenarios without pristine reference images.
|
||||
\item Comprehensive validation of the proposed metrics against traditional methods and subjective Mean Opinion Scores (MOS), demonstrating significant improvements in correlation, robustness, and adaptability.
|
||||
\end{itemize}
|
||||
|
||||
The proposed metrics effectively address the limitations of existing approaches, offering robust solutions for evaluating facial images and steganographic distortions. Their ability to bridge the gap between objective computations and human perception marks a significant advancement in the field of IQA.
|
||||
|
||||
\section{Future Work}
|
||||
|
||||
While this thesis has made substantial contributions, several avenues for future research remain:
|
||||
|
||||
\subsection{Hybrid Metrics}
|
||||
|
||||
Future work could explore hybrid approaches that combine the strengths of Full-Reference and No-Reference metrics. Such methods could leverage reference images when available while maintaining the flexibility to operate without references.
|
||||
|
||||
\subsection{Generalization Across Datasets}
|
||||
|
||||
The current metrics were validated on a specific dataset. Future studies should test their performance on larger, more diverse datasets to evaluate their generalizability across different image domains and distortion types.
|
||||
|
||||
\subsection{Adapting to Emerging Distortion Types}
|
||||
|
||||
As steganography and other encoding techniques evolve, new distortion types will emerge. Extending the proposed metrics to handle these distortions will be critical for maintaining their relevance.
|
||||
|
||||
\subsection{Real-Time Applications}
|
||||
|
||||
The computational complexity of learning-based metrics, such as the NRM, limits their use in real-time scenarios. Future research could focus on optimizing these models for real-time performance without sacrificing accuracy.
|
||||
|
||||
\subsection{Integration with Human-Perception Models}
|
||||
|
||||
Incorporating models from neuroscience and psychology into IQA frameworks could further enhance their alignment with human perception. For instance, integrating attention mechanisms to prioritize salient image regions could improve metric performance for facial images.
|
||||
|
||||
\section{Final Remarks}
|
||||
|
||||
This thesis represents a step toward more perceptually aligned IQA metrics, addressing critical gaps in the evaluation of facial images and steganographic distortions. By combining insights from subjective evaluations, objective computations, and neural network-based methods, the proposed metrics offer a robust foundation for future advancements in the field of IQA. Continued research in this area will not only refine these metrics but also expand their applicability to emerging challenges in digital imaging.
|
||||
Reference in New Issue
Block a user