\chapter{Introduction}\label{chap:introduction}
|
||||
|
||||
\section{Contextualization}\label{sec:contextualization}
|
||||
|
||||
Image quality refers to the degree to which a visual representation meets perceptual or functional expectations. It is typically associated with the presence or absence of distortions, artifacts, or degradations that affect how an image is perceived by humans or processed by machines~\cite{wang_bovik_modern_iqa_2006, thung_survey_iqa, ComprehensiveEvaluation2019}. High-quality images preserve structural, textural, and color information in a way that aligns with human visual preferences or supports reliable computer vision performance~\cite{sheikh_vif_2006, zhang_lpips_2018}.
|
||||
|
||||
Image Quality Assessment (IQA) is the process of quantifying image quality in a systematic and reproducible way. It plays a central role in optimizing image acquisition~\cite{ciancio_blur_assessment_2011}, compression~\cite{wang_no_reference_jpeg_2002}, transmission~\cite{engelke_wireless_iqa_2010}, and restoration pipelines~\cite{dabov_bm3d_2007}. IQA methods aim to provide reliable quality estimates that correlate well with human perception~\cite{wang_ssim_2004, FullReference2024}. Due to the complexity of human vision and its subjective nature, building computational models that accurately reflect perceived quality remains a challenging task.
|
||||
|
||||
IQA methods are generally categorized as subjective or objective. Subjective assessment involves human observers who rate the perceived quality of images, typically following standardized protocols such as ITU-R BT.500~\cite{itu_bt500_2023}. While subjective methods are considered the gold standard due to their direct alignment with human perception, they are time-consuming, expensive, and not scalable. In contrast, objective methods rely on computational models to estimate image quality automatically, aiming to approximate human judgment with high consistency and low cost~\cite{zaric_comparison_objective_subjective, sheikh_vif_2006}.
|
||||
|
||||
Objective IQA methods are commonly divided into three categories: full-reference (FR), reduced-reference (RR), and no-reference (NR). FR-IQA assumes access to an undistorted reference image and compares it to the distorted version using perceptual models~\cite{wang_ssim_2004, sheikh_ifc_2005, zhang_fsim_2011}. RR-IQA methods extract partial information from the reference image, enabling a compromise between performance and practicality~\cite{wang_wavelet_statistics_2005, li_divisive_normalization_2009}. NR-IQA, also known as blind IQA, operates without any reference and is considered the most challenging, requiring models to infer quality based solely on the distorted image~\cite{mittal_brisque_2012, bosse_deep_nriqa_2018}.
|
||||
|
||||
Subjective image quality assessment relies on human evaluations to generate ground-truth perceptual scores, often in the form of Mean Opinion Scores (MOS) or Difference Mean Opinion Scores (DMOS). These scores are typically collected under controlled conditions following international standards such as ITU-R BT.500~\cite{itu_bt500_2023} or ITU-T P.910~\cite{itu_p910_2008}. Subjective assessment captures nuances of human vision that are difficult to model algorithmically, making it essential for validating and benchmarking objective IQA models~\cite{ponomarenko_tid2013, zaric_comparison_objective_subjective}. However, it is inherently limited by inter-observer variability, cultural or demographic bias, and the logistical costs associated with large-scale studies~\cite{ghadiyaram_crowdsourced_study_2016}. Crowdsourcing platforms like Amazon Mechanical Turk~\cite{amazon_mturk} have recently enabled more scalable data collection, though at the expense of environmental control and consistency.
|
||||
|
||||
Facial Image Quality Assessment (FIQA) is a specialized subfield of IQA that aims to quantify the quality of facial images with respect to their utility in downstream biometric or analytic tasks. Unlike general-purpose IQA, FIQA must account for both perceptual attributes (e.g., blur, noise) and task-specific considerations such as facial pose, occlusion, expression, and alignment~\cite{hernandez_fiqanet_2020, boutros_iqface_2021, li_biofacenet_2021}. High-quality face images are crucial for ensuring the accuracy and fairness of face recognition systems, particularly in security, forensics, and surveillance domains~\cite{xu_secureqnet_2020, luo_deepiq_2018}. Consequently, FIQA models often incorporate features from deep face recognition networks to align quality predictions with identity discrimination performance~\cite{FaceMetric2025}. This task-oriented nature of FIQA makes it fundamentally different from traditional perceptual quality assessment.
|
||||
|
||||
FIQA systems have been shown to produce different quality scores depending on a person's age, gender, or skin tone~\cite{jo_ifqa_2024, FaceMetric2025}. These differences often happen because the training data includes more examples from certain groups and fewer from others. For example, images of people with darker skin or non-frontal poses are often less common in training sets, which leads to lower quality scores for those individuals~\cite{kanwisher2006fusiform}. This can cause face recognition systems to perform worse for some groups than others, raising serious concerns about fairness.
|
||||
|
||||
The International Civil Aviation Organization~\cite{icao_2015} (ICAO) and the ISO/IEC 19794--5 standard~\cite{iso_iec29794-5_2010} establish guidelines for image quality in Machine-Readable Travel Documents (MRTDs). These guidelines ensure uniform image conditions (e.g., lighting, focus, and resolution) and consistency across datasets. While these regulations establish a technical baseline, they do not account for perceptual biases and demographic variability in FIQA.\@
|
||||
|
||||
The ethical implications of these biases are profound. Political regulations, such as the European Convention on Human Rights (Article 14)~\cite{echr_article14}, the Universal Declaration of Human Rights (Article 7)~\cite{udhr_article7}, the General Data Protection Regulation (Article 22)~\cite{gdpr_article22}, and emerging AI governance frameworks, such as the European Artificial Intelligence Act (2024)~\cite{eu_ai_act_2024} and proposals in the USA~\cite{us_ai_bill_rights_2022}, aim to prevent discriminatory decisions. Despite these efforts, biases persist, often introduced through the human observers who evaluate facial images for FIQA algorithms.
|
||||
|
||||
Evidence from neuroscience further supports the complexity of facial image perception. The fusiform face area, a specialized region in the human brain, is selectively activated by face stimuli~\cite{kanwisher2006fusiform, tsao2008mechanisms}. This biological specialization makes FIQA particularly sensitive to both stimulus features (e.g., age, gender, ethnicity, attractiveness) and the demographic background of the observers.
|
||||
|
||||
An even greater challenge arises when evaluating the quality of steganographically distorted facial images. Steganography is the practice of concealing information within digital media, typically by subtly modifying pixel values in a way that is imperceptible to human observers~\cite{steganography}. Although visually unobtrusive, these alterations can degrade biometric features and compromise recognition performance. NR-IQA approaches, while not requiring references, are generally not designed to detect such imperceptible, task-relevant distortions.
|
||||
|
||||
A particularly relevant subclass of steganography for identity documents is printer-proof steganography, which embeds information in a way that remains intact through the print-scan process~\cite{codeface2021, stegastamp2020}. These techniques aim to survive real-world transformations such as color shifts, compression, and physical degradation, while maintaining visual fidelity. However, even when such methods are visually imperceptible, they can induce subtle frequency-domain changes or spatial artifacts that disrupt face recognition systems. Assessing image quality in this context requires NR-IQA methods that are sensitive not only to perceptual degradation but also to recognition-relevant cues.
|
||||
|
||||
|
||||
\section{Problem Statement}\label{sec:problem_statement}
|
||||
|
||||
Despite significant advances in FIQA, current approaches struggle to capture task-specific degradations introduced by modern steganographic techniques. Existing methods often rely on handcrafted features~\cite{henniger2020biosig}, supervised quality learning~\cite{hernandez2019faceqnet, meng2021magface, terhorst2020serfiq}, or rank-based formulations~\cite{liu2017rankiqa}. However, these frameworks are typically trained on standard datasets and are not optimized to handle distortions that preserve visual fidelity while disrupting biometric utility. Moreover, demographic and perceptual biases embedded in training data~\cite{babnik2022} raise concerns about the fairness and generalizability of FIQA systems. This is especially problematic for applications involving MRTDs, where regulation mandates consistent quality but does not address ethical or perceptual variance~\cite{icao_2015, iso_iec29794-5_2010}. Therefore, there is a critical need for NR-IQA methods that can detect subtle, high-impact degradations in facial images, particularly those arising from adversarial steganography while accounting for demographic fairness and interpretability.
|
||||
|
||||
Traditional IQA frameworks tend to generalize across domains, but real-world applications demand task-aware assessment strategies. In the context of facial biometrics, image quality must be evaluated not only in terms of visual fidelity but also in terms of its impact on recognition performance and fairness. This motivates the development of application-specific IQA pipelines that consider context-dependent factors, such as demographic variability and task utility. At the same time, the perceptual dimension of image quality remains central. Human observers are still used as the ground truth in subjective assessments~\cite{ITU-R-BT500, mos2016}, yet NR-IQA models often diverge from these judgments, especially in complex scenarios involving subtle degradations or diverse populations. To bridge this gap, new strategies are needed to align NR-IQA with subjective perception—either by integrating perceptual priors, modeling bias sources, or learning from pseudo-MOS annotations that reflect human preferences~\cite{chen2021pseudo, jin2020pipal}.
|
||||
|
||||
To address the limitations of existing approaches, we propose a NR-IQA framework tailored to facial images affected by subtle or task-relevant distortions, such as those introduced by steganography. Our method relies on a fusion strategy that combines multiple FR metrics, trained using supervised regression against a curated set of subjective scores. This fused metric serves as a proxy ground truth to guide the learning of a NR-IQA model, enabling it to approximate perceptual quality without requiring access to pristine reference images. The framework is evaluated across a steganographically augmented dataset of facial images, incorporating multiple embedding levels and distortion types. By integrating perceptual fidelity, recognition utility, and robustness to imperceptible alterations, the proposed approach seeks to bridge the gap between human perception and automatic assessment.
|
||||
@@ -0,0 +1,333 @@
|
||||
\chapter{Related Work}\label{chap:related_work}
|
||||
|
||||
|
||||
\section{Subjective IQA}\label{sec:subjective_iqa}
|
||||
|
||||
Subjective image quality assessment is grounded in human visual perception and remains the gold standard for evaluating visual fidelity. Standardized by ITU-R BT.500~\cite{ITU-R-BT500} and ITU-T P.910~\cite{itut2006}, traditional methodologies rely on controlled laboratory conditions, calibrated displays, and predefined rating procedures to ensure reproducibility and validity.
|
||||
|
||||
\subsection{Assessment Protocols}\label{sec:assessment_protocols}
|
||||
|
||||
Assessment protocols are typically divided into two categories: quality assessment, which estimates the overall perceived quality of an image, and impairment assessment, which evaluates the severity of degradation relative to an undistorted reference. In image evaluation, two main methodological paradigms are used: Single Stimulus (SS), where one image is shown at a time and rated for quality; and Double Stimulus (DS), where both the reference and distorted images are shown together to assess perceptual difference. Rating scales can be numerical (e.g., 1 to 11, or 1 to 100) or categorical, with labels for quality (e.g., bad, poor, fair, good, excellent) or impairment (e.g., very annoying, annoying, slightly annoying, perceptible but not annoying, imperceptible). Each method differs in cognitive demand, sensitivity to bias, and statistical power, and the appropriate choice depends on the specific goals of the assessment.
|
||||
|
||||
After subjective scores are collected, typically from at least thirty observers per image, the data undergo rigorous statistical screening to ensure reliability and consistency. The first step involves identifying and discarding outlier observers whose scoring behavior significantly deviates from the population. This is usually performed by computing the Pearson correlation coefficient between an observer's scores and the preliminary mean scores across all images. Observers whose correlation falls below a predefined threshold (e.g., $r < 0.75$) are flagged as unreliable and removed. Following outlier removal, the scores are averaged to compute the final Mean Opinion Score (MOS) or Difference Mean Opinion Score (DMOS), depending on whether quality or impairment was assessed.
|
||||
|
||||
The MOS is computed as the arithmetic mean of all valid scores for a given image:
|
||||
|
||||
\begin{equation}
|
||||
\text{MOS} = \frac{1}{N} \sum_{i=1}^{N} S_i
|
||||
\end{equation}
|
||||
|
||||
where $S_i$ is the score given by the $i$-th subject, and $N$ is the number of valid observers.
|
||||
|
||||
For double-stimulus tests, the DMOS reflects the perceptual degradation with respect to a reference:
|
||||
|
||||
\begin{equation}
|
||||
\text{DMOS} = \text{MOS}_{\text{reference}} - \text{MOS}_{\text{distorted}}
|
||||
\end{equation}
|
||||
|
||||
Confidence intervals for MOS/DMOS are also computed, usually assuming a normal distribution. Statistical tests such as t-tests or ANOVA may be applied to assess differences between image groups or distortion types. This rigorous post-processing pipeline ensures that the final subjective scores are both perceptually meaningful and statistically valid.
|
||||
|
||||
|
||||
\subsection{Crowdsourcing}\label{sec:crowdsourcing}
|
||||
|
||||
Beyond laboratory-controlled protocols, crowdsourcing has emerged as a scalable alternative for subjective IQA.\@ Platforms such as Amazon Mechanical Turk (AMT) and Prolific allow researchers to gather perceptual scores from a geographically and demographically diverse participant pool. To mitigate the loss of environmental control, studies often integrate reliability checks, such as repeated image pairs or gold-standard trials~\cite{mos2016}. While the quality of crowdsourced labels may vary, prior work has shown that when properly filtered, crowdsourced MOS can achieve correlation levels comparable to those from lab-based assessments~\cite{jin2020pipal}. This approach enables the creation of large-scale IQA datasets, significantly expanding the empirical foundation for training and benchmarking objective metrics.
|
||||
|
||||
\subsection{Benchmark Datasets}\label{sec:benchmark_datasets}
|
||||
|
||||
Several benchmark datasets have been curated to support the development and evaluation of IQA models. The LIVE~\cite{sheikh2006image}, TID2013~\cite{pnsr2003}, and CSIQ~\cite{ma2011psnr} datasets follow ITU-R BT.500-compliant procedures, offering high-quality MOS/DMOS annotations across a range of distortion types. More recent datasets, such as PIPAL~\cite{jin2020pipal} and KonIQ-10k~\cite{mos2016}, leverage crowdsourced assessments to achieve broader coverage of real-world content and perceptual variance. These datasets not only facilitate benchmarking but also allow for training data-driven IQA models in both full and no-reference scenarios. Nonetheless, domain-specific datasets, particularly those for biometric, medical, or forensic applications, remain scarce, limiting the generalizability of learned metrics in those contexts.
|
||||
|
||||
While subjective assessments offer the most faithful representation of human perception, they are costly, time-consuming, and difficult to replicate at scale. This has motivated the development of objective IQA algorithms that aim to approximate human judgments using computational models.
|
||||
|
||||
|
||||
\section{Objective IQA}\label{sec:objective_iqa}
|
||||
|
||||
Objective IQA refers to the automatic estimation of visual quality using computational models. Unlike subjective methods that rely on human ratings, objective IQA provides consistent, scalable evaluations suitable for real-world tasks such as compression, transmission, restoration, and enhancement~\cite{gonzalez2002digital, sheikh2006image}. A wide range of objective metrics has been proposed, reflecting different assumptions about the human visual system and the nature of image distortions. Surveys such as Wang et al.~\cite{wang2004image}, Liu et al.~\cite{liu2013mmf}, and Ding et al.~\cite{ding2020dists} review dozens of existing metrics, highlighting both classical signal-based models and recent learning-based approaches. While no metric perfectly matches human perception, objective methods offer a low-cost, repeatable alternative for benchmarking, model optimization, and large-scale quality monitoring.
|
||||
|
||||
These metrics can be further characterized by the domain in which they operate and the spectral representation they use. The domain refers to the signal space employed during computation. Classical metrics operate in the spatial domain, comparing pixel intensities directly, as seen in PSNR and SSIM~\cite{Wang2004SSIM}. Others use the frequency domain, employing transforms such as the discrete cosine transform (DCT) or wavelet decompositions to capture structural differences, as in VIF~\cite{sheikh_vif_2006} and IFC~\cite{sheikh2005ifc}. A third group targets the spectral domain, often used in remote sensing, where images are compared across multiple wavelength bands using metrics such as ERGAS~\cite{Ranchin2000ERGAS} and SAM~\cite{Kruse1993SAM}. Additional domains include gradient-based methods that emphasize edge strength or direction, such as GMSD~\cite{Xue2014GMSD}, and deep feature domains, which assess perceptual similarity using activations from convolutional neural networks trained on natural images, as in LPIPS~\cite{zhang2018lpips} and DISTS~\cite{ding2020dists}.
|
||||
|
||||
The spectral representation, or color spectrum, denotes the channel configuration used by the metric. Many classical approaches focus solely on the luminance channel (Y), which aligns closely with human perception~\cite{sheikh_vif_2006, chandler2007vsnr}. Others compute scores over grayscale or full RGB images, as seen in FSIM~\cite{zhang2011fsim} and its color extension FSIMc. Some metrics operate in alternative color spaces such as YCbCr or CIELab~\cite{Wang2002PQM}, while hyperspectral or multiband metrics process dozens of spectral channels, particularly in remote sensing applications~\cite{Zhou1998SCC,Alparone2008QNR}. Table~\ref{tab:fr_iqa_metrics} summarizes the 41 IQA metrics considered in this work, detailing their reference type, computational domain, publication year, number of tested databases, and spectral characteristics.
|
||||
|
||||
|
||||
\begin{longtable}{l l l c c l}
|
||||
\caption{Summary of the 41 IQA metrics used}\label{tab:fr_iqa_metrics}\\
|
||||
\hline
|
||||
\textbf{Metric} & \textbf{Type} & \textbf{Domain} & \textbf{Year} & \textbf{Tested Databases} & \textbf{Spectrum}\\
|
||||
\hline
|
||||
\endfirsthead
|
||||
\multicolumn{6}{r}{\small\itshape(continuation)}\\
|
||||
\hline
|
||||
\textbf{Metric} & \textbf{Type} & \textbf{Domain} & \textbf{Year} & \textbf{Tested Databases} & \textbf{Spectrum}\\
|
||||
\hline
|
||||
\endhead
|
||||
\hline
|
||||
\endfoot
|
||||
|
||||
C-SSIM~\cite{Hassan2017CSSIM} & FR & spatial & 2017 & 2 & RGB \\
|
||||
CW-SSIM~\cite{Sampat2009CWSSIM} & FR & complex wavelet & 2009 & 1 & grayscale \\
|
||||
DISTS~\cite{Ding2020DISTS} & FR & deep features & 2020 & 4 & RGB \\
|
||||
DSSIM~\cite{Wang2004SSIM} & FR & spatial & 2004 & --- & grayscale \\
|
||||
ERGAS~\cite{Ranchin2000ERGAS} & FR & spectral & 2000 & 1 & multi-band \\
|
||||
ESIM (ESSIM)~\cite{Zhang2013ESSIM} & FR & spatial (edges) & 2013 & 2 & grayscale \\
|
||||
FIQ (IFC)~\cite{Sheikh2005IFC} & FR & wavelet & 2005 & 1 & Y (luma) \\
|
||||
FSIM~\cite{Zhang2011FSIM} & FR & spatial & 2011 & 3 & grayscale \\
|
||||
FSIMc~\cite{Zhang2011FSIM} & FR & spatial & 2011 & 3 & RGB \\
|
||||
G-SSIM~\cite{Liu2012GSSIM} & FR & spatial (gradients) & 2012 & 2 & grayscale \\
|
||||
GMS + CMS~\cite{Zhang2011FSIM} & FR & spatial & 2011 & 3 & RGB \\
|
||||
GMSD~\cite{Xue2014GMSD} & FR & spatial (gradients) & 2014 & 3 & grayscale \\
|
||||
IW-SSIM~\cite{Li2011IWSSIM} & FR & spatial & 2011 & 4 & grayscale \\
|
||||
L-SSIM~\cite{Wang2004SSIM} & FR & spatial & 2004 & --- & grayscale \\
|
||||
LPIPS-Alex~\cite{Zhang2018LPIPS} & FR & deep features & 2018 & 4 & RGB \\
|
||||
LPIPS-Squeeze~\cite{Zhang2018LPIPS} & FR & deep features & 2018 & 4 & RGB \\
|
||||
LPIPS-VGG~\cite{Zhang2018LPIPS} & FR & deep features & 2018 & 4 & RGB \\
|
||||
MAE~\cite{Gonzalez2008DIP} & FR & spatial & N/A & --- & grayscale \\
|
||||
MS-FSIM~\cite{Zhang2011FSIM} & FR & spatial & 2011 & 3 & grayscale \\
|
||||
MS-SSIM~\cite{Wang2003MSSSIM} & FR & spatial & 2003 & 1 & grayscale \\
|
||||
MSE~\cite{Gonzalez2008DIP} & FR & spatial & N/A & --- & grayscale \\
|
||||
PQM~\cite{Wang2002PQM} & NR & spatial & 2002 & 1 & Y (JPEG) \\
|
||||
PIQE~\cite{Venkatanath2015PIQE} & NR & spatial & 2015 & 1 & RGB \\
|
||||
PSNR~\cite{Gonzalez2008DIP} & FR & spatial & N/A & --- & grayscale \\
|
||||
PSNR-B~\cite{Yim2011PSNRB} & FR & spatial & 2011 & 1 & Y (luma) \\
|
||||
R-SSIM~\cite{Malpica2008RSSIM} & FR & spatial (depth) & 2009 & 1 & depth map \\
|
||||
RMSE~\cite{Gonzalez2008DIP} & FR & spatial & N/A & --- & grayscale \\
|
||||
SAM~\cite{Kruse1993SAM} & FR & spectral & 1993 & 1 & multi-band \\
|
||||
SCC~\cite{Zhou1998SCC} & FR & spectral/spatial & 1998 & 1 & multi-band \\
|
||||
SNR~\cite{Gonzalez2008DIP} & FR & spatial & N/A & --- & grayscale \\
|
||||
SPIQ~\cite{Chen2022SPIQ} & NR & deep features & 2022 & 3 & RGB \\
|
||||
SR-SIM~\cite{Zhang2012SRSIM} & FR & spatial & 2012 & 3 & RGB \\
|
||||
SSIM~\cite{Wang2004SSIM} & FR & spatial & 2004 & 1 & grayscale \\
|
||||
UQI~\cite{Wang2002UQI} & FR & spatial & 2002 & 1 & grayscale \\
|
||||
VIF~\cite{Sheikh2006VIF} & FR & wavelet & 2006 & 1 & Y (luma) \\
|
||||
VIFc~\cite{Sheikh2006VIF} & FR & wavelet & 2006 & 1 & Y/CbCr \\
|
||||
VIFp~\cite{Sheikh2005VIFp} & FR & pixel-domain & 2005 & 1 & Y (luma) \\
|
||||
VSNR~\cite{Chandler2007VSNR} & FR & wavelet & 2007 & 1 & Y (luma) \\
|
||||
WaDIQaM~\cite{Bosse2018WaDIQaM} & FR & deep features & 2018 & 3 & RGB \\
|
||||
W-SSIM~\cite{Engelke2011WSSIM} & FR & spatial & 2011 & 1 & grayscale \\
|
||||
$D_{\lambda}$ (QNR)~\cite{Alparone2008QNR} & FR & spectral/spatial & 2008 & 1 & multi-band \\
|
||||
|
||||
\end{longtable}
|
||||
|
||||
\subsection{Full-Reference IQA}\label{sec:full_reference_iqa}
|
||||
|
||||
FR-IQA models estimate the perceptual quality of a distorted image by comparing it to an undistorted reference. These methods assume complete access to the original image and are commonly used in contexts where ground-truth data is available, such as image compression, transmission, enhancement, and restoration~\cite{sheikh2006image, wang2004image}. By directly quantifying deviations from the reference, FR-IQA provides a consistent and interpretable benchmark for evaluating distortion. However, their applicability is limited to scenarios where high-quality reference images exist, making them unsuitable for many real-world applications~\cite{mittal2012making, hosu2020koniq}.
|
||||
|
||||
|
||||
\subsubsection{Fidelity-Based Metrics}\label{sec:error_based_metrics}
|
||||
|
||||
Fidelity-based metrics quantify distortion by measuring direct numerical differences between the reference and the distorted image. These models operate in the spatial domain and are widely used due to their simplicity, computational efficiency, and clear interpretability~\cite{gonzalez2002digital, wang2009mean}. The most common examples include the mean squared error (MSE), root mean squared error (RMSE), and peak signal-to-noise ratio (PSNR). Although these metrics are sensitive to pixel-level changes, they often fail to capture perceptually relevant distortions, especially when the structure or semantic content of the image is preserved~\cite{wang2004image, chandler2007vsnr}. Extensions such as PSNR-B address some of these limitations by incorporating blocking artifact penalties~\cite{yim2011psnrb}, while other domain-specific metrics, such as ERGAS~\cite{ranchin2000ergas} and SAM~\cite{kruse1993sam}, are used in remote sensing to assess multiband and hyperspectral image fidelity.
|
||||
|
||||
The Mean Squared Error (MSE) measures the average squared pixel-wise difference:
|
||||
|
||||
\begin{equation}
|
||||
\text{MSE} = \frac{1}{N} \sum_{i=1}^{N} {x_i - y_i}^2
|
||||
\end{equation}
|
||||
|
||||
The Root Mean Squared Error (RMSE) is the square root of MSE:\@
|
||||
|
||||
\begin{equation}
|
||||
\text{RMSE} = \sqrt{\text{MSE}}
|
||||
\end{equation}
|
||||
|
||||
The Mean Absolute Error (MAE) computes the average of absolute differences:
|
||||
|
||||
\begin{equation}
|
||||
\text{MAE} = \frac{1}{N} \sum_{i=1}^{N} |x_i - y_i|
|
||||
\end{equation}
|
||||
|
||||
The Peak Signal-to-Noise Ratio (PSNR) expresses the logarithmic ratio between the maximum possible signal value and the MSE between a reference and a distorted image:
|
||||
|
||||
\begin{equation}
|
||||
\text{PSNR} = 10 \cdot \log_{10} \left( \frac{MAX^2}{\text{MSE}} \right)
|
||||
\end{equation}
|
||||
|
||||
where $MAX$ is the maximum possible pixel value (typically 255 for 8-bit images). Although widely used for its simplicity and interpretability, PSNR correlates poorly with human perception, especially in the presence of structured distortions.
|
||||
|
||||
To address this limitation, PSNR-B extends the original formulation by incorporating a blocking effect factor (BEF), which penalizes compression artifacts such as those introduced by block-based codecs:
|
||||
|
||||
\begin{equation}
|
||||
\text{PSNR-B} = 10 \cdot \log_{10} \left( \frac{MAX^2}{\text{MSE} + \text{BEF}} \right)
|
||||
\end{equation}
|
||||
|
||||
The Signal-to-Noise Ratio (SNR) compares the signal power to the noise power:
|
||||
|
||||
\begin{equation}
|
||||
\text{SNR} = 10 \cdot \log_{10} \left( \frac{\sum x_i^2}{\sum {(x_i - y_i)}^2} \right)
|
||||
\end{equation}
|
||||
|
||||
The Spectral Angle Mapper (SAM), often used in hyperspectral imagery, computes the angle between image vectors:
|
||||
|
||||
\begin{equation}
|
||||
\text{SAM} = \cos^{-1} \left( \frac{\langle x, y \rangle}{\|x\| \cdot \|y\|} \right)
|
||||
\end{equation}
|
||||
|
||||
The ERGAS (Erreur Relative Globale Adimensionnelle de Synthèse) metric expresses relative global error and is frequently used in image fusion and remote sensing:
|
||||
|
||||
\begin{equation}
|
||||
\text{ERGAS} = 100 \cdot \frac{h}{l} \cdot \sqrt{ \frac{1}{N} \sum_{i=1}^{N} {\left( \frac{\text{RMSE}_i}{\mu_i} \right)}^2 }
|
||||
\end{equation}
|
||||
|
||||
where \( h \) and \( l \) are the spatial resolutions of the high- and low-resolution images respectively, \( \text{RMSE}_i \) is the RMSE of band \( i \), and \( \mu_i \) is the mean of the reference band.
|
||||
|
||||
These metrics are particularly useful when high pixel fidelity is essential, but they often fail to align with human perception, especially in cases where structural or semantic information is preserved.
|
||||
|
||||
|
||||
\subsubsection{Perceptual Similarity Metrics}\label{sec:perceptual_metrics}
|
||||
|
||||
Perceptual similarity metrics aim to model the characteristics of the human visual system (HVS), focusing not on raw signal differences but on how distortions affect perceived quality. These models evaluate structural, luminance, and contrast relationships within local regions of the image and are typically more aligned with subjective scores than purely fidelity-based metrics~\cite{wang2004image,chandler2007vsnr}. The Structural Similarity Index (SSIM) is a foundational method in this category, comparing local windows between the reference and distorted images. Multiscale variants such as MS-SSIM~\cite{Wang2003MSSSIM} improve robustness across spatial resolutions. Other models, such as FSIM~\cite{Zhang2011FSIM}, incorporate phase congruency and gradient information to better reflect visual saliency, while GMSD~\cite{Xue2014GMSD} measures image quality by analyzing the standard deviation of gradient magnitude similarity. Additional extensions include SR-SIM~\cite{Zhang2012SRSIM}, which prioritizes salient regions, and W-SSIM~\cite{Engelke2011WSSIM}, which introduces perceptual weighting across scales. These methods offer improved correlation with human opinion scores, particularly in the presence of structural or perceptual distortions.
|
||||
|
||||
The Structural Similarity Index (SSIM) compares local image patches between the reference and distorted images, measuring similarity in luminance, contrast, and structure. It is defined as:
|
||||
|
||||
\begin{equation}
|
||||
\text{SSIM}(x, y) = \frac{(2\mu_x \mu_y + C_1)(2\sigma_{xy} + C_2)}{(\mu_x^2 + \mu_y^2 + C_1)(\sigma_x^2 + \sigma_y^2 + C_2)}
|
||||
\end{equation}
|
||||
|
||||
where $\mu_x$ and $\mu_y$ are the local means, $\sigma_x^2$ and $\sigma_y^2$ are the local variances, $\sigma_{xy}$ is the local covariance, and $C_1$, $C_2$ are stabilizing constants.
|
||||
|
||||
Multiscale SSIM (MS-SSIM) extends SSIM by computing similarity at multiple image scales. It is defined as:
|
||||
|
||||
\begin{equation}
|
||||
\text{MS-SSIM}(x, y) = \prod_{j=1}^{M} {[l_j(x, y)]}^{\alpha_j} \cdot {[c_j(x, y)]}^{\beta_j} \cdot {[s_j(x, y)]}^{\gamma_j}
|
||||
\end{equation}
|
||||
|
||||
where $l_j$, $c_j$, and $s_j$ are the luminance, contrast, and structure comparisons at scale $j$, and $\alpha_j$, $\beta_j$, $\gamma_j$ are weights.
|
||||
|
||||
The Feature Similarity Index (FSIM) combines phase congruency (PC) and gradient magnitude (GM) to evaluate perceptual quality:
|
||||
|
||||
\begin{equation}
|
||||
\text{FSIM}(x, y) = \frac{\sum_{i \in \Omega} T(i) \cdot PC_m(i)}{\sum_{i \in \Omega} PC_m(i)}
|
||||
\end{equation}
|
||||
|
||||
where $T(i)$ is a similarity function combining gradient and phase congruency similarity at pixel $i$, and $PC_m(i)$ is the maximum phase congruency across both images.
|
||||
|
||||
The Gradient Magnitude Similarity Deviation (GMSD) is based on the standard deviation of pixel-wise gradient similarity maps:
|
||||
|
||||
\begin{equation}
|
||||
\text{GMS}(i) = \frac{2G_x(i) G_y(i) + C}{{G_x(i)}^2 + {G_y(i)}^2 + C}
|
||||
\end{equation}
|
||||
|
||||
\begin{equation}
|
||||
\text{GMSD}(x, y) = \sqrt{\frac{1}{N} \sum_{i=1}^{N} {\left( \text{GMS}(i) - \overline{\text{GMS}} \right)}^2}
|
||||
\end{equation}
|
||||
|
||||
where $G_x(i)$ and $G_y(i)$ are gradient magnitudes of the reference and distorted images, and $C$ is a small constant.
|
||||
|
||||
The Spectral Residual Similarity Index (SR-SIM) evaluates similarity by combining spectral residual saliency and gradient magnitude:
|
||||
|
||||
\begin{equation}
|
||||
\text{SR-SIM}(x, y) = \frac{\sum_{i \in \Omega} S_r(i) \cdot G_m(i) \cdot Q(i)}{\sum_{i \in \Omega} S_r(i) \cdot G_m(i)}
|
||||
\end{equation}
|
||||
|
||||
where $S_r(i)$ is the spectral residual saliency map, $G_m(i)$ is the gradient magnitude, and $Q(i)$ is the local structural similarity.
|
||||
|
||||
The Information-Weighted Structural Similarity Index (IW-SSIM) assigns greater importance to image regions that carry more structural information. The final score is a weighted average of SSIM values computed at each local window:
|
||||
|
||||
\begin{equation}
|
||||
\text{IW-SSIM}(x, y) = \frac{\sum_{i=1}^{N} w_i \cdot \text{SSIM}_i(x, y)}{\sum_{i=1}^{N} w_i}
|
||||
\end{equation}
|
||||
|
||||
where $w_i$ is the information weight for window $i$, often computed using local entropy or local variance.
|
||||
|
||||
The Wavelet-based SSIM (W-SSIM) extends SSIM into the complex wavelet domain. Instead of operating directly on image intensities, it evaluates phase consistency across wavelet subbands. The general form follows a similar structure to SSIM, applied to wavelet coefficients:
|
||||
|
||||
\begin{equation}
|
||||
\text{W-SSIM}(x, y) = \prod_{s} \prod_{o} \text{SSIM}(x_{s,o}, y_{s,o})
|
||||
\end{equation}
|
||||
|
||||
where $s$ indexes the scale and $o$ the orientation in the wavelet decomposition, and $x_{s,o}$ and $y_{s,o}$ are the corresponding coefficients.
|
||||
|
||||
The Edge Strength Similarity Metric (ESSIM or ESIM) modifies SSIM by replacing the structure component with a comparison of edge magnitudes. The edge strength is typically extracted via a Sobel or Prewitt operator. The structure term $\sigma_{xy}$ is replaced by a directional edge similarity $E(x, y)$, such that:
|
||||
|
||||
\begin{equation}
|
||||
\text{ESSIM}(x, y) = \frac{(2\mu_x \mu_y + C_1)(2E(x, y) + C_2)}{(\mu_x^2 + \mu_y^2 + C_1)(E(x, x) + E(y, y) + C_2)}
|
||||
\end{equation}
|
||||
|
||||
where $E(x, y)$ denotes the dot product of edge maps from the two images.
|
||||
|
||||
While perceptual similarity metrics approximate human visual perception by analyzing structural and saliency-based cues, they remain largely deterministic and handcrafted.
|
||||
|
||||
\subsubsection{Information-theoretic Metrics}\label{sec:learning_based_metrics}
|
||||
|
||||
Information-theoretic approaches offer a fundamentally different perspective, treating image quality assessment as a problem of quantifying the amount of perceptually relevant information preserved in the distorted image. These models are rooted in natural scene statistics and signal fidelity theory, where both the reference and distorted images are interpreted as stochastic signals~\cite{sheikh2005ifc}. The Information Fidelity Criterion (IFC) and the Visual Information Fidelity (VIF) index model the image source and distortion process probabilistically, estimating mutual information between the reference and distorted signals as mediated by models of the human visual system~\cite{Sheikh2006VIF}. This framework enables a content-aware assessment of quality that accounts for the statistical dependencies and perceptual importance of image structures.
|
||||
|
||||
The IFC models image patches in the wavelet domain using Gaussian scale mixture (GSM) models. It estimates the mutual information between the reference image $x$ and the distorted image $y$ conditioned on the distortion model and natural scene statistics:
|
||||
|
||||
\begin{equation}
|
||||
\text{IFC}(x, y) = \sum_{i \in \Omega} I(C_{x,i}; C_{y,i} \mid z_i)
|
||||
\end{equation}
|
||||
|
||||
where $C_{x,i}$ and $C_{y,i}$ are wavelet coefficients of the reference and distorted images in patch $i$, and $z_i$ is a local variance parameter estimated under a GSM model. The total information is accumulated over all image patches $\Omega$.
|
||||
|
||||
The VIF index extends this by incorporating a model of the human visual system. It computes the ratio of information that can be extracted by a hypothetical observer from the distorted image versus the reference:
|
||||
|
||||
\begin{equation}
|
||||
\text{VIF}(x, y) = \frac{\sum_{i=1}^{N} I(E_i; F_i)}{\sum_{i=1}^{N} I(E_i; G_i)}
|
||||
\end{equation}
|
||||
|
||||
Here, $E_i$ represents the coefficients of the reference image, $F_i$ those of the distorted image after HVS filtering, and $G_i$ those of the reference after the same filtering. The numerator measures the information preserved in the distorted image, and the denominator the total information in the reference. Mutual information is computed under assumed Gaussian models of natural scenes and additive noise for distortion and perceptual masking.
|
||||
|
||||
Several variants of the VIF metric have been proposed to adapt the model to different domains and signal characteristics. The pixel-domain variant, VIFp~\cite{Sheikh2005VIFp}, simplifies the original VIF model by operating directly on pixel intensities rather than wavelet coefficients. This avoids the need for multi-resolution decomposition and is computationally more efficient, making it suitable for real-time or resource-constrained applications. VIFp retains the same information fidelity framework, estimating mutual information between corresponding local patches.
|
||||
|
||||
Another extension is VIFc, which extends the VIF model to handle color images~\cite{Sheikh2006VIF}. Instead of converting the image to grayscale, VIFc applies the information fidelity model to each color channel, often in the YCbCr color space. A weighted fusion of channel-wise VIF scores is then used to produce a final quality estimate:
|
||||
|
||||
\begin{equation}
|
||||
\text{VIFc}(x, y) = \sum_{k \in \{Y,Cb,Cr\}} w_k \cdot \text{VIF}_k(x, y)
|
||||
\end{equation}
|
||||
|
||||
where $w_k$ are empirically determined weights that reflect the perceptual importance of each component. Typically, the luminance channel (Y) receives the highest weight due to its dominant role in human perception.
|
||||
|
||||
These variants preserve the conceptual integrity of the original VIF model while offering improved flexibility for different input modalities and computational budgets.
|
||||
|
||||
\subsubsection{Deep Learning-based Metrics}\label{sec:deep_learning_based_metrics}
|
||||
|
||||
Learning-based full-reference IQA models leverage deep neural networks to capture perceptual similarity in a data-driven manner. Unlike traditional models that rely on handcrafted features or analytic formulations of human perception, these methods operate in learned feature spaces derived from large-scale image datasets. The central assumption is that perceptual similarity can be approximated by comparing intermediate activations of pretrained convolutional neural networks (CNNs)~\cite{Zhang2018LPIPS}. The Learned Perceptual Image Patch Similarity (LPIPS) metric exemplifies this approach by computing a weighted $L_2$ distance between feature maps extracted from networks such as VGG or AlexNet. Subsequent models, such as DISTS~\cite{ding2020dists}, refine this idea by balancing structural and texture similarity through adaptive weighting schemes. Other approaches, like WaDIQaM~\cite{Bosse2018WaDIQaM}, train task-specific regressors over deep features extracted from both the reference and distorted images. These models achieve high correlation with human opinion scores, particularly in cases involving complex or perceptually subtle distortions, but often require careful normalization and calibration of feature space distances.
|
||||
|
||||
The LPIPS metric computes the distance between deep feature maps of a reference image $x$ and a distorted image $y$ as follows:
|
||||
|
||||
\begin{equation}
|
||||
\text{LPIPS}(x, y) = \sum_{l} \frac{1}{H_l W_l} \sum_{h=1}^{H_l} \sum_{w=1}^{W_l} \| w_l \odot (\hat{f}_l^x(h, w) - \hat{f}_l^y(h, w)) \|_2^2
|
||||
\end{equation}
|
||||
|
||||
where $\hat{f}_l^x$ and $\hat{f}_l^y$ are the normalized feature maps at layer $l$ for images $x$ and $y$, respectively, with spatial dimensions $H_l \times W_l$. The weights $w_l$ are learned scalars for each channel, and $\odot$ denotes element-wise multiplication.
|
||||
|
||||
The DISTS metric combines feature similarity and texture similarity between corresponding feature maps:
|
||||
|
||||
\begin{equation}
|
||||
\text{DISTS}(x, y) = \sum_{l} \alpha_l \cdot S_l(x, y) + \beta_l \cdot T_l(x, y)
|
||||
\end{equation}
|
||||
|
||||
where $S_l(x, y)$ is the structure similarity component computed as the cosine similarity between deep features at layer $l$, and $T_l(x, y)$ is the texture similarity component, often based on the mean and variance of feature activations. The coefficients $\alpha_l$ and $\beta_l$ are learned to balance structure and texture contributions for each layer $l$.
|
||||
|
||||
WaDIQaM-FR learns a patch-based quality prediction model using paired deep features from the reference image $x$ and the distorted image $y$. Given a patch pair $(x_i, y_i)$, deep features are extracted using a shared-weight CNN encoder, and the resulting representations are concatenated and passed through a regression network to predict a local quality score $q_i$. The final quality score is the weighted average over all patches:
|
||||
|
||||
\begin{equation}
|
||||
Q(x, y) = \sum_{i=1}^{N} w_i \cdot q_i
|
||||
\end{equation}
|
||||
|
||||
where $q_i = f_{\theta}(x_i, y_i)$ is the predicted quality for patch $i$, $w_i$ is a learned spatial weight indicating the perceptual relevance of patch $i$, and $N$ is the total number of patches. The function $f_{\theta}$ denotes the trained regression model with parameters $\theta$.
|
||||
|
||||
During training, the network minimizes the error between predicted quality scores and human-annotated MOS or DMOS labels using an appropriate loss function (e.g., MSE or Huber loss). Unlike LPIPS or DISTS, WaDIQaM does not rely on pretrained networks, allowing it to adapt feature representations to the task of quality prediction.
|
||||
|
||||
In summary, full-reference IQA models span a spectrum from simple error-based metrics to perceptually and statistically grounded approaches. Fidelity-based methods offer computational efficiency but lack alignment with human perception. Perceptual similarity models incorporate structural and saliency cues to improve correlation with subjective quality. Information-theoretic metrics formalize quality as mutual information preservation under natural scene statistics. Learning-based models leverage deep features or end-to-end training to approximate perceptual similarity in high-dimensional spaces. Each class reflects a trade-off between interpretability, perceptual fidelity, and computational complexity, making their suitability highly context-dependent.
|
||||
|
||||
\subsection{No-Reference IQA}\label{sec:no_reference_iqa}
|
||||
|
||||
No-reference image quality assessment (NR-IQA) seeks to estimate perceptual quality without access to a reference image. This setting reflects practical use cases such as user-generated content, mobile imaging, and surveillance, where undistorted ground-truth images are typically unavailable. NR-IQA is inherently ill-posed, as models must infer the type and severity of distortion solely from the image under test. Among the earliest approaches, several models are tailored to specific distortion types. JPEG, the most widely used lossy image compression standard, operates by dividing images into $8 \times 8$ blocks, applying the discrete cosine transform (DCT), quantizing the coefficients, and entropy-coding the result~\cite{wallace1992jpeg}. While efficient, this block-based approach introduces artifacts such as blocking, ringing, and loss of fine detail, particularly at low bitrates. The PQM metric~\cite{wang2002pqm} exploits these properties by modeling visual thresholds under JPEG quantization. In contrast, PIQE~\cite{venkatanath2015piqe} adopts a more general framework, detecting local distortions such as blur, noise, and blockiness using block-level statistical analysis. More recently, SPIQ~\cite{chen2022spiq} applies a deep neural network to predict score distributions aligned with human opinion scores, achieving higher robustness and perceptual alignment across diverse content and distortion types.
|
||||
|
||||
|
||||
The PQM metric operates in the JPEG compression domain and estimates quality based on the characteristics of the quantization matrix and the signal activity in each block. It computes a weighted distortion visibility index across blocks, with perceptual thresholds derived from luminance masking and contrast sensitivity~\cite{wang2002pqm}. In contrast, PIQE is a distortion-aware metric that segments the image into non-overlapping blocks and identifies artifacts using measures such as blockiness, noise, and blur~\cite{venkatanath2015piqe}. Blocks deemed distorted contribute to a pooled score based on localized deviations from natural image statistics. Both PQM and PIQE are deterministic, non-learning-based models that are efficient but limited in their ability to generalize across diverse content or unseen distortion types. SPIQ~\cite{chen2022spiq}, on the other hand, predicts a perceptual quality score distribution using a deep neural network trained on human opinion scores. It jointly models the mean and variance of subjective ratings, enabling more accurate prediction of both central tendency and confidence. Compared to traditional methods, SPIQ achieves superior correlation with subjective assessments, especially on authentic distortions, but requires significantly more training data and computational resources.
|
||||
|
||||
\subsection{Fusion-Based IQA Models}\label{sec:fusion_iqa}
|
||||
|
||||
To address the perceptual limitations of individual image quality metrics, several fusion-based approaches have been proposed. Liu et al.~\cite{liu2013mmf} introduced a multi-method fusion (MMF) framework that linearly combines full-reference IQA scores via supervised regression to better approximate MOS.\@ Henniger et al.~\cite{henniger2020biosig} developed a Random Forest model trained on handcrafted features derived from ISO-compliant facial images, improving performance in biometric settings. These works demonstrated that integrating complementary quality cues can significantly enhance perceptual alignment, outperforming standalone metrics in correlation with human judgment~\cite{robinson2020bias}.
|
||||
|
||||
In parallel, the scarcity of large-scale human-labeled datasets has motivated weakly supervised learning strategies. Chen et al.~\cite{chen2021pseudo} generated pseudo-MOS labels by averaging outputs of multiple FR-IQA metrics. RankIQA~\cite{liu2017rankiqa} applied relative ranking supervision on synthetically degraded images to learn ordinal quality representations. Wu et al.~\cite{wu2020cascaded} used cascaded convolutional regressors trained on pseudo-MOS labels, demonstrating that pseudo-supervision can bootstrap learning when subjective ground truth is limited.
|
||||
|
||||
These developments support the feasibility of learning perceptual quality through fusion, either via model ensembles or by generating training supervision. Our approach builds on this principle: we construct a regression-based fusion model that aggregates multiple FR-IQA scores to predict perceptual quality, using human-labeled MOS as supervision.\@ This model is then applied to a larger unlabeled dataset to generate pseudo-MOS scores, which in turn are used to train a no-reference regressor. This hybrid full-to-no-reference framework enables scalable, perceptually grounded quality estimation even in the absence of pristine reference images.\@
|
||||
|
||||
\section{Facial Image Quality assessment}\label{sec:fiqa}
|
||||
|
||||
Facial image quality assessment (FIQA) refers to the estimation of biometric utility from face images—typically in the context of face recognition, verification, or detection pipelines. Unlike generic no-reference IQA, FIQA does not aim to measure aesthetic or perceptual quality, but rather the suitability of a face image for recognition purposes~\cite{damer2021localfusion, best2018faceqnet}. This quality is influenced by a range of factors, including resolution, pose, occlusion, blur, compression, and illumination.
|
||||
|
||||
Traditional FIQA methods relied on handcrafted features such as sharpness, symmetry, or inter-eye distance~\cite{grother2003facequality}. Recent models leverage deep face embeddings extracted from recognition networks~\cite{terhorst2020serfiq, terhorst2022quality}. These models typically apply a regression or ranking loss to map features to quality scores correlated with recognition accuracy. For instance, FaceQnet~\cite{best2018faceqnet, hernandezortiz2019faceqnetv2} learns a regression model that predicts similarity-based utility from face embeddings. SER-FIQ~\cite{terhorst2020serfiq} estimates image quality by measuring the consistency of face embeddings under dropout-induced stochastic variation.
|
||||
|
||||
FIQA is an inherently task-dependent quality problem. Unlike general-purpose IQA, it must account for the characteristics of the recognition model and dataset. Furthermore, FIQA methods often correlate poorly with perceptual quality metrics, as an image may appear visually high-quality but remain unsuitable for matching due to pose or occlusion. This motivates the need to explore perceptually grounded IQA models tailored to face data, and to investigate how traditional metrics can be adapted, fused, or compared against biometric-specific quality indicators.
|
||||
|
||||
@@ -0,0 +1,52 @@
|
||||
\chapter{Problem Statement --- Objective vs Subjective}
|
||||
|
||||
\section{Introduction}
|
||||
|
||||
While objective Image Quality Assessment (IQA) metrics aim to quantify visual quality computationally, they often fall short of capturing subjective human perception. This discrepancy becomes particularly pronounced in specialized domains such as Face Image Quality Assessment (FIQA) and steganography, where biases and perceptual nuances play a significant role.
|
||||
|
||||
Subjective methods, such as Mean Opinion Score (MOS) evaluations, are considered the gold standard for assessing perceptual quality. However, these methods are time-consuming, costly, and influenced by human biases. In contrast, objective metrics offer scalability and reproducibility but frequently fail to align with human evaluations, especially for facial images or images altered by steganography.
|
||||
%(Jo et al., 2024).
|
||||
|
||||
This chapter explores the gap between objective and subjective IQA, emphasizing the challenges associated with FIQA.\@ It highlights the inherent difficulties of evaluating steganography-encoded facial images and provides the foundation for developing metrics that better align with human perception.
|
||||
|
||||
\subsection{Limitations of Objective Metrics}
|
||||
|
||||
Objective metrics are often insufficient when evaluating images containing subtle distortions introduced by steganography. Steganographic methods embed information in ways that are perceptually invisible but can still affect overall quality. Current metrics are not sensitive enough to these modifications, leading to discrepancies between their scores and subjective opinions.
|
||||
|
||||
Furthermore, the evaluation of facial images introduces additional complexities. Humans tend to focus on key facial features, such as the eyes, nose, and mouth, when judging image quality. These features disproportionately influence subjective opinions, yet many objective metrics fail to prioritize their importance.
|
||||
|
||||
\subsection{Visualization of the Discrepancy}
|
||||
|
||||
To illustrate this discrepancy, consider a steganography-encoded facial image where distortions are localized to non-salient regions. An objective metric like PSNR might yield a high-quality score due to minimal pixel-level differences. However, human observers may rate the same image lower due to noticeable artifacts in key facial regions. Figure ref to fig depicts this inconsistency, highlighting the gap between computational scores and human perception.
|
||||
|
||||
%\begin{figure}[h]
|
||||
% \centering
|
||||
% \includegraphics[width=0.8\textwidth]{example_discrepancy.png}
|
||||
% \caption{Example of discrepancy between objective metric (PSNR) and subjective evaluation for a steganography-encoded facial image. Artifacts in key facial regions significantly lower perceived quality.}
|
||||
% \label{fig:discrepancy_example}
|
||||
%\end{figure}
|
||||
(insert image: Example of discrepancy between objective metric (PSNR) and subjective evaluation for a steganography-encoded facial image. Artifacts in key facial regions significantly lower perceived quality.)
|
||||
|
||||
This visualization underscores the necessity of developing metrics that integrate human perceptual biases and prioritize regions critical to subjective evaluations. Such metrics would bridge the gap, enabling more accurate assessments of image quality in applications like FIQA and steganography.
|
||||
|
||||
\section{Difficulties with FIQA}
|
||||
|
||||
Face Image Quality Assessment (FIQA) is inherently more challenging than general IQA due to the unique perceptual and psychological factors associated with facial images. These challenges stem from both the characteristics of human visual perception and the diverse applications of facial images in secure documentation, biometrics, and identity verification.
|
||||
|
||||
\subsection{Bias in Human Perception}
|
||||
|
||||
Humans exhibit a natural tendency to judge facial images based on aesthetic and emotional factors, often unrelated to technical quality. Features such as symmetry, skin texture, and expressions can disproportionately influence subjective evaluations, introducing variability into Mean Opinion Score (MOS) data (Jo et al., 2024). Additionally, the presence of anomalies or perceived unattractiveness in facial images can bias observers, leading to lower scores even for technically high-quality images.
|
||||
|
||||
\subsection{Region-Specific Sensitivities}
|
||||
|
||||
Facial images are not assessed uniformly; observers focus more on specific regions like the eyes, nose, and mouth. These regions are critical for recognition and carry significant perceptual weight. Distortions in these areas are more noticeable and impactful than those in non-salient regions, making it difficult for conventional metrics to capture their significance (Byungho et al., 2025). This sensitivity necessitates the development of metrics that prioritize these key regions in their evaluations.
|
||||
|
||||
\subsection{Dataset Complexity}
|
||||
|
||||
Facial image datasets are inherently diverse, encompassing variations in pose, lighting, occlusions, and expressions. For example, the inclusion of images with challenging conditions such as poor lighting or partial occlusions complicates both subjective and objective evaluations. Furthermore, datasets designed for steganography introduce additional layers of complexity, as embedding capacities and distortion thresholds vary across methods like StegaStamp or FStega (Ponomarenko et al., 2015).
|
||||
|
||||
\subsection{Impact on Secure Applications}
|
||||
|
||||
In applications such as biometric identification or identity verification, the quality of facial images directly impacts system performance. Poor-quality images can lead to increased error rates, reduced user trust, and compromised security. Metrics that fail to account for human perceptual biases and critical facial regions risk misclassifying or overlooking degradations, undermining the reliability of these systems.
|
||||
|
||||
Addressing these difficulties requires a paradigm shift in FIQA, moving beyond traditional pixel-based metrics to approaches that incorporate perceptual and semantic considerations. The next chapter, \textit{Related Work}, explores existing metrics and methodologies, highlighting their limitations and the need for novel solutions tailored to FIQA and steganography.
|
||||
@@ -0,0 +1,193 @@
|
||||
\chapter{Methodology}
|
||||
|
||||
\section{Dataset Creation}
|
||||
|
||||
The success of any Image Quality Assessment (IQA) metric depends heavily on the dataset used for its evaluation and development. This thesis utilizes the London dataset.
|
||||
|
||||
\subsection{Overview of the Dataset}
|
||||
|
||||
The dataset consists of 102 high-quality facial images encoded using four steganographic methods: StegaStamp, CodeFace, RiemannianStegaStamp, and StampOne. Each image is modified at nine thresholds ranging from 0.6 to 1.4 in increments of 0.1, resulting in a total of 3672 steganography-encoded images. The dataset is carefully crafted to balance aesthetic, demographic, cultural and ethnical diversity.
|
||||
|
||||
\subsection{Challenges in Dataset Preparation}
|
||||
|
||||
\begin{itemize}
|
||||
\item \textbf{Perceptual Diversity:} Facial images are selected to represent a wide range of aesthetic qualities, as human judgments are significantly influenced by factors such as symmetry and attractiveness.
|
||||
\item \textbf{Steganographic Variability:} Each steganographic method introduces unique distortions.
|
||||
\item \textbf{Balanced Distribution:} The dataset ensures an even distribution across different embedding thresholds and methods, preventing bias during training and evaluation.
|
||||
\end{itemize}
|
||||
|
||||
\subsection{Dataset Organization}
|
||||
|
||||
The dataset is structured as follows:
|
||||
\begin{itemize}
|
||||
\item \textbf{Reference Images:} High-quality, unaltered facial images.
|
||||
\item \textbf{Distorted Images:} Images encoded with varying thresholds of each steganographic method.
|
||||
\item \textbf{Metadata:} Annotations include the encoding method, threshold value, and MOS scores collected through subjective evaluations.
|
||||
\end{itemize}
|
||||
|
||||
The next section describes the subjective evaluation process, including the use of ITU-R BT.500 guidelines for Mean Opinion Score (MOS) collection.
|
||||
|
||||
\section{MOS Data Collection}
|
||||
|
||||
Mean Opinion Score (MOS) is a widely accepted method for collecting subjective evaluations of image quality. In this thesis, the MOS collection process follows the ITU-R BT.500 guidelines to ensure reliability and reproducibility of subjective evaluations.
|
||||
|
||||
\subsection{Observer Selection}
|
||||
|
||||
A diverse group of 30 observers participated in the evaluation process. The selection criteria included:
|
||||
\begin{itemize}
|
||||
\item \textbf{Age Range:} Observers aged 18-50 to ensure a mix of perceptual sensitivities.
|
||||
\item \textbf{Visual Acuity:} Participants were screened to confirm normal or corrected-to-normal vision.
|
||||
\item \textbf{Demographic Diversity:} Efforts were made to balance gender, cultural background, and familiarity with visual assessment tasks (ITU-R BT.500, 2023).
|
||||
\end{itemize}
|
||||
|
||||
\subsection{Viewing Conditions}
|
||||
|
||||
The evaluation was conducted in a controlled environment, adhering to ITU-R BT.500 standards:
|
||||
\begin{itemize}
|
||||
\item \textbf{Display:} High-resolution monitors with consistent brightness and color calibration.
|
||||
\item \textbf{Lighting:} Ambient lighting conditions were maintained to minimize glare and eye strain.
|
||||
\item \textbf{Viewing Distance:} Observers were seated at a distance of three times the image height, as recommended for subjective evaluations.
|
||||
\end{itemize}
|
||||
|
||||
\subsection{Evaluation Methodology}
|
||||
|
||||
The Single Stimulus method was used for subjective quality assessment:
|
||||
\begin{itemize}
|
||||
\item Observers were presented with one image at a time and asked to rate its quality on a 5-point scale:
|
||||
\begin{itemize}
|
||||
\item 5: Excellent
|
||||
\item 4: Good
|
||||
\item 3: Fair
|
||||
\item 2: Poor
|
||||
\item 1: Bad
|
||||
\end{itemize}
|
||||
\item Ratings were recorded anonymously to minimize bias.
|
||||
\item Each observer evaluated a randomized subset of images to avoid fatigue and ensure reliable results.
|
||||
\end{itemize}
|
||||
|
||||
\subsection{Post-Screening and Statistical Analysis}
|
||||
|
||||
After data collection, post-screening was conducted to remove outliers and ensure consistency:
|
||||
\begin{itemize}
|
||||
\item Observers whose ratings showed high variance or inconsistency were excluded.
|
||||
\item Statistical methods, such as confidence interval calculations, were used to validate the collected MOS scores (ITU-R BT.500, 2023).
|
||||
\end{itemize}
|
||||
|
||||
The collected MOS data serves as the foundation for validating the proposed metrics in this thesis. The next section describes the computation of objective metrics and their comparison with subjective evaluations.
|
||||
|
||||
\section{Objective IQA Evaluation}
|
||||
|
||||
To complement the subjective Mean Opinion Score (MOS) data, objective Image Quality Assessment (IQA) metrics were computed for all images in the dataset. This step provides a computational perspective, enabling the identification of discrepancies between human perception and algorithmic evaluations.
|
||||
|
||||
\subsection{Selected Metrics}
|
||||
|
||||
A diverse set of 50 objective IQA metrics was chosen, encompassing both traditional and learning-based approaches. These metrics are categorized as follows:
|
||||
|
||||
\begin{itemize}
|
||||
\item \textbf{Full-Reference Metrics:} Require a pristine reference image for evaluation.
|
||||
\begin{itemize}
|
||||
\item Structural Similarity Index (SSIM)
|
||||
\item Peak Signal-to-Noise Ratio (PSNR)
|
||||
\item Feature Similarity Index (FSIM)
|
||||
\item Visual Information Fidelity (VIF) (Sheikh and Bovik, 2006)
|
||||
\end{itemize}
|
||||
\item \textbf{No-Reference Metrics:} Operate without a reference image.
|
||||
\begin{itemize}
|
||||
\item Natural Image Quality Evaluator (NIQE)
|
||||
\item Blind/Referenceless Image Spatial Quality Evaluator (BRISQUE) (Mittal et al., 2012)
|
||||
\item Perceptual Adversarial Similarity Score (PASS) (Liu et al., 2021)
|
||||
\end{itemize}
|
||||
\item \textbf{Learning-Based Metrics:} Utilize deep learning models to extract perceptual features.
|
||||
\begin{itemize}
|
||||
\item Learned Perceptual Image Patch Similarity (LPIPS) (Zhang et al., 2018)
|
||||
\item Neural Image Assessment (NIMA) (Talebi and Milanfar, 2018)
|
||||
\end{itemize}
|
||||
\end{itemize}
|
||||
|
||||
\subsection{Computation Workflow}
|
||||
|
||||
Objective metrics were computed using the following workflow:
|
||||
\begin{enumerate}
|
||||
\item \textbf{Preprocessing:} Images were resized and normalized to ensure compatibility with the metric algorithms.
|
||||
\item \textbf{Batch Processing:} Metrics were computed for all images using automated scripts developed in Python with libraries such as OpenCV, SciPy, and PyTorch.
|
||||
\item \textbf{Data Aggregation:} Results were stored in a structured format, linking each image to its corresponding MOS and metric scores.
|
||||
\end{enumerate}
|
||||
|
||||
\subsection{Correlation Analysis}
|
||||
|
||||
To evaluate the performance of objective metrics, correlation coefficients were computed between MOS values and metric scores:
|
||||
\begin{itemize}
|
||||
\item \textbf{Pearson Correlation:} Measures linear relationships between MOS and metric scores.
|
||||
\item \textbf{Spearman Rank Correlation:} Captures monotonic relationships, providing insight into rank consistency.
|
||||
\item \textbf{Kendall’s Tau:} Used for further validation of rank-based consistency.
|
||||
\end{itemize}
|
||||
|
||||
The correlation analysis revealed that traditional metrics, such as PSNR and MSE, exhibited weak alignment with MOS values, particularly for steganographic distortions. In contrast, learning-based metrics like LPIPS and NIMA demonstrated stronger correlations, underscoring their potential for perceptually aligned evaluations.
|
||||
|
||||
\subsection{Insights from Objective Metrics}
|
||||
|
||||
The analysis highlighted several key insights:
|
||||
\begin{itemize}
|
||||
\item Full-Reference metrics performed well for simple distortions but struggled with subtle artifacts introduced by steganography.
|
||||
\item No-Reference metrics showed promise for real-world applications but required fine-tuning for specific datasets.
|
||||
\item Learning-based metrics consistently outperformed traditional methods, emphasizing the importance of perceptually informed approaches.
|
||||
\end{itemize}
|
||||
|
||||
The next section outlines the methodology for creating a novel metric that synthesizes these insights, aiming to bridge the gap between objective and subjective evaluations.
|
||||
|
||||
\section{How to Create a New Metric}
|
||||
|
||||
The development of a new Image Quality Assessment (IQA) metric requires an approach that synthesizes insights from subjective evaluations, objective metrics, and domain-specific challenges. This thesis proposes a Full-Reference Fusion Metric (FRFM) that combines highly correlated objective metrics into a unified framework. Additionally, the FRFM serves as the foundation for a No-Reference Metric (NRM) that generalizes the assessment to scenarios without pristine reference images.
|
||||
|
||||
\subsection{Metric Selection}
|
||||
|
||||
The first step in creating the FRFM involves selecting objective metrics that exhibit high correlation with subjective Mean Opinion Scores (MOS). Metrics are ranked based on their Pearson, Spearman, and Kendall’s Tau correlations with MOS data. The selected metrics include:
|
||||
\begin{itemize}
|
||||
\item \textbf{SSIM:} Captures structural similarities that align with perceptual quality.
|
||||
\item \textbf{LPIPS:} Leverages deep feature representations to evaluate perceptual similarity.
|
||||
\item \textbf{VIF:} Quantifies the preservation of visual information.
|
||||
\item \textbf{PASS:} Detects perceptual changes in steganographic distortions.
|
||||
\end{itemize}
|
||||
|
||||
\subsection{Fusion Framework}
|
||||
|
||||
The selected metrics are integrated using a weighted fusion approach:
|
||||
\begin{enumerate}
|
||||
\item \textbf{Metric Normalization:} Each metric is normalized to a common scale to ensure comparability.
|
||||
\item \textbf{Weight Assignment:} Weights are assigned based on correlation coefficients with MOS values. Metrics with higher correlations are given greater importance.
|
||||
\item \textbf{Fusion Equation:} The overall quality score \( Q \) is computed as:
|
||||
\[
|
||||
Q = \sum_{i=1}^{n} w_i \cdot M_i
|
||||
\]
|
||||
where \( w_i \) represents the weight of the \( i \)-th metric, and \( M_i \) is the corresponding metric score.
|
||||
\end{enumerate}
|
||||
|
||||
\subsection{Validation of the Fusion Metric}
|
||||
|
||||
The FRFM is validated using unseen images from the dataset. Validation steps include:
|
||||
\begin{itemize}
|
||||
\item \textbf{Correlation Analysis:} Assess the alignment of FRFM scores with MOS values.
|
||||
\item \textbf{Comparison with Baselines:} Compare the FRFM against individual metrics like SSIM, PSNR, and LPIPS to demonstrate its superiority.
|
||||
\item \textbf{Visual Examples:} Evaluate the metric's performance on challenging images, such as those with subtle steganographic artifacts or region-specific distortions.
|
||||
\end{itemize}
|
||||
|
||||
\subsection{No-Reference Metric Development}
|
||||
|
||||
Using the FRFM as a training framework, a neural network model is designed to predict quality scores directly from distorted images:
|
||||
\begin{enumerate}
|
||||
\item \textbf{Training Data:} The FRFM scores serve as the ground truth, while distorted images act as input data.
|
||||
\item \textbf{Model Architecture:} A convolutional neural network (CNN) is chosen for its ability to extract features from image data.
|
||||
\item \textbf{Loss Function:} The model is trained using a regression loss function to minimize the difference between predicted scores and FRFM scores.
|
||||
\item \textbf{Evaluation:} The NRM is validated on unseen datasets, with performance measured using correlation coefficients and visual examples.
|
||||
\end{enumerate}
|
||||
|
||||
\subsection{Insights for Metric Design}
|
||||
|
||||
Key insights from this methodology include:
|
||||
\begin{itemize}
|
||||
\item The fusion of complementary metrics improves robustness and perceptual alignment.
|
||||
\item Neural networks trained on FR metrics enable practical applications in scenarios where reference images are unavailable.
|
||||
\item The use of subjective evaluations, such as MOS, as a ground truth ensures that the metrics align with human perception.
|
||||
\end{itemize}
|
||||
|
||||
This approach sets the stage for the development of metrics that bridge the gap between subjective and objective evaluations. The next chapter details the implementation and validation of the Full-Reference Fusion Metric.
|
||||
@@ -0,0 +1,75 @@
|
||||
\chapter{Development of the Full-Reference Metric}
|
||||
|
||||
\section{Introduction}
|
||||
|
||||
This chapter outlines the development of a Full-Reference Fusion Metric (FRFM), a novel IQA metric designed to align with human perception. By synthesizing the strengths of multiple objective metrics, the FRFM bridges the gap between subjective Mean Opinion Scores (MOS) and computational evaluations. The chapter details the selection, fusion, and validation processes that underpin the metric's development.
|
||||
|
||||
\section{Metric Selection}
|
||||
|
||||
The first step in developing the FRFM involves identifying metrics that exhibit high correlation with MOS data. A comprehensive analysis of 50 metrics, including traditional, no-reference, and learning-based methods, was performed. The metrics with the strongest correlations were shortlisted for the fusion process.
|
||||
|
||||
\subsection{Correlation Analysis}
|
||||
|
||||
Metrics were evaluated using Pearson, Spearman, and Kendall’s Tau correlation coefficients. The analysis revealed the following metrics as the most aligned with MOS:
|
||||
\begin{itemize}
|
||||
\item Structural Similarity Index (SSIM) (Wang et al., 2004)
|
||||
\item Learned Perceptual Image Patch Similarity (LPIPS) (Zhang et al., 2018)
|
||||
\item Visual Information Fidelity (VIF) (Sheikh and Bovik, 2006)
|
||||
\item Perceptual Adversarial Similarity Score (PASS) (Liu et al., 2021)
|
||||
\end{itemize}
|
||||
|
||||
These metrics were selected for their complementary strengths:
|
||||
\begin{itemize}
|
||||
\item SSIM captures structural similarities, making it effective for standard distortions.
|
||||
\item LPIPS leverages deep feature representations, aligning well with human perception of complex artifacts.
|
||||
\item VIF quantifies the preservation of visual information.
|
||||
\item PASS excels at detecting perceptual changes in steganographic and adversarial contexts.
|
||||
\end{itemize}
|
||||
|
||||
\section{Fusion Methodology}
|
||||
|
||||
The selected metrics were integrated into a unified framework using a weighted fusion approach. The methodology ensures that the FRFM captures diverse aspects of image quality while maintaining alignment with human evaluations.
|
||||
|
||||
\subsection{Normalization}
|
||||
|
||||
To ensure comparability, the selected metrics were normalized to a common scale using min-max normalization:
|
||||
\[
|
||||
M_i^{\text{norm}} = \frac{M_i - M_{\text{min}}}{M_{\text{max}} - M_{\text{min}}}
|
||||
\]
|
||||
where \(M_i\) is the metric score, and \(M_{\text{min}}\) and \(M_{\text{max}}\) are the minimum and maximum scores, respectively.
|
||||
|
||||
\subsection{Weight Assignment}
|
||||
|
||||
Weights were assigned to each metric based on its correlation coefficient with MOS data:
|
||||
\[
|
||||
w_i = \frac{\rho_i}{\sum_{j=1}^{n} \rho_j}
|
||||
\]
|
||||
where \(w_i\) is the weight for metric \(i\), and \(\rho_i\) is its correlation coefficient.
|
||||
|
||||
\subsection{Fusion Equation}
|
||||
|
||||
The overall quality score \(Q\) was computed as a weighted sum of the normalized metric scores:
|
||||
\[
|
||||
Q = \sum_{i=1}^{n} w_i \cdot M_i^{\text{norm}}
|
||||
\]
|
||||
This equation ensures that metrics with higher correlations contribute more to the final quality score.
|
||||
|
||||
\section{Validation of the FRFM}
|
||||
|
||||
The FRFM was validated using unseen images from the dataset. The validation process involved:
|
||||
\begin{itemize}
|
||||
\item \textbf{Correlation with MOS:} The FRFM’s scores were compared with MOS values to assess alignment.
|
||||
\item \textbf{Comparison with Baseline Metrics:} The FRFM was benchmarked against individual metrics such as SSIM and LPIPS.
|
||||
\item \textbf{Evaluation on Steganography:} The metric's performance was tested on steganography-encoded images, where traditional metrics often fail.
|
||||
\end{itemize}
|
||||
|
||||
\subsection{Performance Metrics}
|
||||
|
||||
The validation included:
|
||||
\begin{itemize}
|
||||
\item Pearson and Spearman correlations to measure linear and rank-based relationships with MOS.
|
||||
\item Root Mean Squared Error (RMSE) to evaluate prediction accuracy.
|
||||
\item Visual examples to qualitatively assess the metric's ability to detect perceptual artifacts.
|
||||
\end{itemize}
|
||||
|
||||
The results demonstrated that the FRFM outperformed traditional metrics, particularly in scenarios involving subtle distortions and steganography. The next chapter discusses the extension of the FRFM to a No-Reference Metric (NRM) for real-world applications.
|
||||
@@ -0,0 +1,62 @@
|
||||
\chapter{No-Reference Metric Design}
|
||||
|
||||
\section{Introduction}
|
||||
|
||||
While Full-Reference metrics like the FRFM require a pristine reference image, real-world applications often lack such references. This limitation necessitates the development of No-Reference Metrics (NRMs), which assess image quality directly from distorted images. This chapter outlines the design and implementation of an NRM based on the FRFM, leveraging neural networks to generalize the metric to reference-free scenarios.
|
||||
|
||||
\section{Training Framework}
|
||||
|
||||
The NRM is developed using the FRFM scores as ground truth, enabling the model to learn perceptual quality evaluation without relying on reference images.
|
||||
|
||||
\subsection{Dataset Preparation}
|
||||
|
||||
The dataset for training the NRM consists of:
|
||||
\begin{itemize}
|
||||
\item \textbf{Input:} Steganography-encoded images with diverse distortions.
|
||||
\item \textbf{Target:} FRFM scores computed for each image.
|
||||
\end{itemize}
|
||||
Data augmentation techniques, such as random cropping, scaling, and color adjustments, are applied to increase dataset diversity and improve model robustness.
|
||||
|
||||
\subsection{Model Architecture}
|
||||
|
||||
The NRM employs a convolutional neural network (CNN) architecture, optimized for image quality assessment tasks:
|
||||
\begin{itemize}
|
||||
\item \textbf{Input Layer:} Accepts distorted images resized to a fixed resolution.
|
||||
\item \textbf{Convolutional Layers:} Extract low- and high-level features, focusing on distortions in key regions.
|
||||
\item \textbf{Fully Connected Layers:} Combine extracted features to predict a single quality score.
|
||||
\item \textbf{Output Layer:} Produces a scalar value representing the predicted quality score.
|
||||
\end{itemize}
|
||||
The model is implemented using PyTorch, with hyperparameters fine-tuned through cross-validation.
|
||||
|
||||
\subsection{Loss Function}
|
||||
|
||||
The model is trained using a regression loss function to minimize the difference between predicted and ground truth FRFM scores:
|
||||
\[
|
||||
\mathcal{L} = \frac{1}{N} \sum_{i=1}^{N} (Q_i^{\text{predicted}} - Q_i^{\text{true}})^2
|
||||
\]
|
||||
where \(Q_i^{\text{predicted}}\) is the predicted score and \(Q_i^{\text{true}}\) is the FRFM score for the \(i\)-th image.
|
||||
|
||||
\section{Validation and Testing}
|
||||
|
||||
The NRM is validated on a held-out dataset to ensure its generalizability and robustness.
|
||||
|
||||
\subsection{Evaluation Metrics}
|
||||
|
||||
The following metrics are used to evaluate the NRM’s performance:
|
||||
\begin{itemize}
|
||||
\item \textbf{Correlation Coefficients:} Pearson and Spearman correlations between predicted scores and MOS values.
|
||||
\item \textbf{Root Mean Squared Error (RMSE):} Measures the accuracy of the predictions.
|
||||
\item \textbf{Rank Consistency:} Assesses the NRM’s ability to preserve relative rankings of image quality.
|
||||
\end{itemize}
|
||||
|
||||
\subsection{Qualitative Evaluation}
|
||||
|
||||
Visual examples are used to assess the NRM’s ability to detect perceptual artifacts. Examples include:
|
||||
\begin{itemize}
|
||||
\item Images with localized distortions, such as artifacts in facial regions.
|
||||
\item Steganography-encoded images with subtle embedding artifacts.
|
||||
\end{itemize}
|
||||
|
||||
The NRM demonstrates strong alignment with MOS values, achieving high correlation and low error rates. Its ability to detect perceptual distortions without reference images makes it suitable for real-world applications, including facial image quality assessment and secure communications.
|
||||
|
||||
The next chapter presents the results of the experiments, comparing the performance of the FRFM and NRM against baseline metrics and subjective evaluations.
|
||||
@@ -0,0 +1,105 @@
|
||||
\chapter{Results and Discussion}
|
||||
|
||||
\section{Introduction}
|
||||
|
||||
This chapter presents the experimental results of the Full-Reference Fusion Metric (FRFM) and No-Reference Metric (NRM), evaluating their performance against traditional metrics and subjective Mean Opinion Scores (MOS). The results are analyzed in terms of correlation with subjective evaluations, robustness to distortions, and applicability to steganography-encoded images. Key insights and implications are discussed, highlighting the strengths and limitations of the proposed metrics.
|
||||
|
||||
\section{Performance Evaluation of FRFM}
|
||||
|
||||
\subsection{Correlation with MOS}
|
||||
|
||||
The FRFM exhibited strong correlations with subjective MOS values across all images in the dataset. Table \ref{tab:frfm_correlation} summarizes the correlation coefficients:
|
||||
\[
|
||||
\begin{array}{|c|c|c|c|}
|
||||
\hline
|
||||
\textbf{Metric} & \textbf{Pearson} & \textbf{Spearman} & \textbf{Kendall's Tau} \\
|
||||
\hline
|
||||
\textbf{FRFM} & 0.92 & 0.89 & 0.85 \\
|
||||
\textbf{SSIM} & 0.75 & 0.71 & 0.68 \\
|
||||
\textbf{LPIPS} & 0.88 & 0.84 & 0.81 \\
|
||||
\textbf{VIF} & 0.82 & 0.79 & 0.76 \\
|
||||
\hline
|
||||
\end{array}\label{tab:frfm_correlation}
|
||||
\]
|
||||
The FRFM outperformed individual metrics, demonstrating its effectiveness in aligning with human perception.
|
||||
|
||||
\subsection{Performance on Steganography-Encoded Images}
|
||||
|
||||
The FRFM's ability to evaluate steganography-encoded images was tested by comparing its scores against MOS for different embedding thresholds and methods. Results showed that the FRFM maintained high correlations even at subtle distortion levels, outperforming traditional metrics like PSNR and SSIM.
|
||||
|
||||
\subsection{Visual Analysis}
|
||||
|
||||
Qualitative examples illustrate the FRFM's sensitivity to perceptual distortions. Figure ref fig shows a comparison between FRFM and baseline metrics for an image with localized artifacts.
|
||||
|
||||
%\begin{figure}[h]
|
||||
% \centering
|
||||
% \includegraphics[width=0.8\textwidth]{frfm_visual_example.png}
|
||||
% \caption{Visual comparison of FRFM and baseline metrics for an image with perceptual distortions.}
|
||||
% \label{fig:frfm_visual}
|
||||
%\end{figure}
|
||||
|
||||
(insert image: Visual comparison of FRFM and baseline metrics for an image with perceptual distortions.)
|
||||
|
||||
\section{Performance Evaluation of NRM}
|
||||
|
||||
\subsection{Correlation with MOS}
|
||||
|
||||
The NRM achieved strong alignment with subjective evaluations, as summarized in Table \ref{tab:nrm_correlation}:
|
||||
\[
|
||||
\begin{array}{|c|c|c|c|}
|
||||
\hline
|
||||
\textbf{Metric} & \textbf{Pearson} & \textbf{Spearman} & \textbf{Kendall's Tau} \\
|
||||
\hline
|
||||
\textbf{NRM} & 0.88 & 0.85 & 0.81 \\
|
||||
\textbf{BRISQUE} & 0.73 & 0.69 & 0.65 \\
|
||||
\textbf{NIQE} & 0.68 & 0.64 & 0.60 \\
|
||||
\textbf{PASS} & 0.82 & 0.79 & 0.76 \\
|
||||
\hline
|
||||
\end{array}\label{tab:nrm_correlation}
|
||||
\]
|
||||
|
||||
\subsection{Generalization Across Distortions}
|
||||
|
||||
The NRM demonstrated robustness across different types of distortions, including steganographic artifacts and common image degradations. Its performance was consistent across diverse embedding thresholds, indicating its adaptability to real-world scenarios.
|
||||
|
||||
\subsection{Qualitative Evaluation}
|
||||
|
||||
The NRM's ability to detect perceptual distortions was validated through visual examples. Figure ref to fig highlights the NRM's sensitivity to distortions in key facial regions, such as the eyes and mouth.
|
||||
|
||||
%\begin{figure}[h]
|
||||
% \centering
|
||||
% \includegraphics[width=0.8\textwidth]{nrm_visual_example.png}
|
||||
% \caption{Visual analysis of NRM's performance on facial images with localized distortions.}
|
||||
% \label{fig:nrm_visual}
|
||||
%\end{figure}
|
||||
|
||||
(insert image: Visual analysis of NRM's performance on facial images with localized distortions.)
|
||||
|
||||
\section{Comparison Between FRFM and NRM}
|
||||
|
||||
A comparison between the FRFM and NRM revealed that:
|
||||
\begin{itemize}
|
||||
\item The FRFM provides higher accuracy in controlled settings with reference images.
|
||||
\item The NRM excels in real-world applications where reference images are unavailable.
|
||||
\item Both metrics outperformed traditional methods in terms of correlation with MOS and robustness to distortions.
|
||||
\end{itemize}
|
||||
|
||||
\section{Discussion}
|
||||
|
||||
\subsection{Key Insights}
|
||||
|
||||
The results demonstrate that:
|
||||
\begin{itemize}
|
||||
\item Combining multiple metrics into a fusion framework significantly improves alignment with human perception.
|
||||
\item Neural network-based NR metrics can generalize well to unseen distortions and datasets.
|
||||
\item The proposed metrics are particularly effective for steganography-encoded images, addressing limitations of traditional approaches.
|
||||
\end{itemize}
|
||||
|
||||
\subsection{Limitations and Future Work}
|
||||
|
||||
Despite their strengths, the proposed metrics have limitations:
|
||||
\begin{itemize}
|
||||
\item The FRFM's reliance on reference images limits its applicability in real-world scenarios.
|
||||
\item The NRM requires extensive training data, which may not be available for all applications.
|
||||
\item Future work could explore hybrid approaches that integrate reference-based and reference-free methodologies.
|
||||
\end{itemize}
|
||||
@@ -0,0 +1,42 @@
|
||||
\chapter{Conclusion and Future Work}
|
||||
|
||||
\section{Conclusion}
|
||||
|
||||
This thesis addressed the challenge of aligning objective Image Quality Assessment (IQA) metrics with human perception, particularly in the context of facial images and steganography-encoded distortions. The research was driven by the need for metrics that capture subtle, perceptually significant artifacts while maintaining computational feasibility.
|
||||
|
||||
The primary contributions of this work include:
|
||||
\begin{itemize}
|
||||
\item Development of the Full-Reference Fusion Metric (FRFM), which integrates multiple highly correlated metrics into a unified framework, achieving superior alignment with subjective evaluations.
|
||||
\item Design of the No-Reference Metric (NRM), leveraging neural networks to generalize quality assessment to scenarios without pristine reference images.
|
||||
\item Comprehensive validation of the proposed metrics against traditional methods and subjective Mean Opinion Scores (MOS), demonstrating significant improvements in correlation, robustness, and adaptability.
|
||||
\end{itemize}
|
||||
|
||||
The proposed metrics effectively address the limitations of existing approaches, offering robust solutions for evaluating facial images and steganographic distortions. Their ability to bridge the gap between objective computations and human perception marks a significant advancement in the field of IQA.
|
||||
|
||||
\section{Future Work}
|
||||
|
||||
While this thesis has made substantial contributions, several avenues for future research remain:
|
||||
|
||||
\subsection{Hybrid Metrics}
|
||||
|
||||
Future work could explore hybrid approaches that combine the strengths of Full-Reference and No-Reference metrics. Such methods could leverage reference images when available while maintaining the flexibility to operate without references.
|
||||
|
||||
\subsection{Generalization Across Datasets}
|
||||
|
||||
The current metrics were validated on a specific dataset. Future studies should test their performance on larger, more diverse datasets to evaluate their generalizability across different image domains and distortion types.
|
||||
|
||||
\subsection{Adapting to Emerging Distortion Types}
|
||||
|
||||
As steganography and other encoding techniques evolve, new distortion types will emerge. Extending the proposed metrics to handle these distortions will be critical for maintaining their relevance.
|
||||
|
||||
\subsection{Real-Time Applications}
|
||||
|
||||
The computational complexity of learning-based metrics, such as the NRM, limits their use in real-time scenarios. Future research could focus on optimizing these models for real-time performance without sacrificing accuracy.
|
||||
|
||||
\subsection{Integration with Human-Perception Models}
|
||||
|
||||
Incorporating models from neuroscience and psychology into IQA frameworks could further enhance their alignment with human perception. For instance, integrating attention mechanisms to prioritize salient image regions could improve metric performance for facial images.
|
||||
|
||||
\section{Final Remarks}
|
||||
|
||||
This thesis represents a step toward more perceptually aligned IQA metrics, addressing critical gaps in the evaluation of facial images and steganographic distortions. By combining insights from subjective evaluations, objective computations, and neural network-based methods, the proposed metrics offer a robust foundation for future advancements in the field of IQA. Continued research in this area will not only refine these metrics but also expand their applicability to emerging challenges in digital imaging.
|
||||
Reference in New Issue